Combi Boiler Pipes Explained: Which Pipe Is Which Under Your Boiler
Hertfordshire, Bedfordshire & Cambridgeshire
A combi boiler normally has five main pipes underneath it: the gas supply, the heating flow out to the radiators, the heating return back from them, the cold mains coming in and the hot water going out to your taps. There are usually two more: a small copper pipe from the pressure relief valve that runs outside, and a plastic condensate pipe that drains to a waste or drain. Knowing which is which helps you spot a leak, describe a fault and understand what an engineer is talking about, but the gas pipe and anything inside the boiler are for a Gas Safe registered engineer only.
In short
- Five main pipes: gas in, heating flow, heating return, cold mains in, hot water out.
- Two drain pipes: pressure relief valve discharge (copper, to outside) and condensate (plastic, to a drain).
- Heating flow and return are usually 22mm. Cold in and hot out are usually 15mm.
- The order of the pipes under the boiler varies by make and model. The installation manual has the diagram for yours.
- A dripping relief valve pipe or a frozen condensate pipe are the two pipework problems homeowners notice most.

New boiler?
Get an instant estimate for a new boiler
Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.
The pipes under a combi boiler
Most combi boilers have a row of valves and pipes along the bottom. Here is what each one does and how you can usually recognise it.
| Pipe | What it does | Typical size | How to recognise it |
|---|---|---|---|
| Gas supply | Brings gas from the meter to the boiler | 15mm or 22mm at the boiler, depending on the model. The supply pipe is sized by the installer, commonly 22mm | Runs back towards the gas meter. Often marked or labelled for gas |
| Heating flow | Carries hot water out to the radiators | 22mm | Gets hot first when the heating comes on |
| Heating return | Brings cooler water back from the radiators | 22mm | Warms up after the flow. The magnetic filter is usually fitted on this pipe |
| Cold mains in | Brings cold water from your mains supply to be heated | 15mm | Stays cold. Often has a valve with a blue handle or marking |
| Hot water out | Sends hot water to your taps and shower | 15mm | Gets hot within seconds of a hot tap being opened |
| Pressure relief valve discharge | Lets water out safely if system pressure gets too high | 15mm copper | Runs through the wall to the outside, usually turned back towards the wall |
| Condensate | Drains the acidic water a condensing boiler makes | Plastic, usually around 22mm inside, larger outside | White or grey plastic pipe running to a drain, waste pipe or soakaway |
On many combis you will also see a filling loop, a short braided hose or built-in link with a valve at each end. It joins the cold mains to the heating side so you can top up the pressure. The order of the connections along the bottom is different from one make and model to the next, so always check the diagram in the installation or user guide for your boiler rather than assuming.
If any of these pipes is leaking or behaving oddly, our boiler repair service can find out why.
How to tell the heating flow from the return
This is the question we are asked most. The simplest ways to tell:
- Look for labels. Many installers label pipes, and the valves on some boilers are marked for flow and return.
- Check the manual. The installation manual shows the connection layout for your boiler.
- Watch as the heating starts. With the heating off and cool, turn it on. The flow pipe warms up first and gets hotter. The return follows a little later and runs cooler. Hover your hand near the pipes rather than gripping them, because they get hot enough to burn.
- Follow the filter. If you have a magnetic system filter, it is normally fitted on the return pipe just before it goes into the boiler.
Do not open, close or adjust any valve unless your user guide tells you to. Closing the heating valves with the boiler running can make it overheat and lock out.
How water moves through a combi boiler
A combi does two jobs with one burner, and the pipes make more sense once you see how.
When the heating is on, the pump pushes hot water out through the flow pipe, around every radiator and back through the return. This water stays in a sealed loop, which is why it has pressure and why the gauge on the front of the boiler matters. Our guide to a boiler that keeps losing pressure explains what happens when water escapes from that loop.
When you open a hot tap, a part called the diverter valve switches the heat away from the radiators and into a small plate heat exchanger. Cold mains water comes in, passes through that heat exchanger and leaves as hot water to your tap. The mains water and heating water never mix. They only pass heat to each other.
That is why a fault with the diverter valve can leave you with heating but no hot water, or the reverse. Our guide to no hot water but heating works covers that in more detail.
The two drain pipes: relief valve and condensate
Pressure relief valve pipe
Every sealed heating system has a pressure relief valve, a safety device that opens if the pressure gets too high. The copper pipe from it runs outside so that any water, which could be very hot, is released safely. It should be dry. Drips or white staining on the wall beneath it mean the valve has been opening, usually because the expansion vessel has lost its charge or the filling loop has been left open.
Condensate pipe
Condensing boilers produce slightly acidic water, which drains through a plastic pipe to a drain, waste pipe or soakaway. Manufacturers usually ask for a wider pipe where it runs outside, because a narrow external pipe is much more likely to freeze. Ideal’s installation guidance, for example, asks for external condensate pipe of at least 30mm internal diameter. When the pipe freezes, the boiler backs up and locks out, often with a gurgling noise. Our frozen condensate pipe guide shows how to thaw it safely.
Common pipework problems
| Problem | What you notice | Likely cause | Who fixes it |
|---|---|---|---|
| Relief valve pipe dripping outside | Wet patch or staining on the wall below the copper pipe | High pressure, expansion vessel or a worn valve | Gas Safe engineer |
| Frozen condensate pipe | Boiler stops in freezing weather, gurgling noise | Ice in the plastic pipe outside | You can thaw it. An engineer can reroute or upsize it |
| Drip from a valve under the boiler | Water on the floor or boiler casing | Loose or worn valve, fitting or washer | Engineer or plumber |
| Pressure creeping up | Gauge rises towards 3 bar with the heating off | Filling loop not fully closed, or an internal fault letting mains water in | Engineer |
| Flow hot, return cold, radiators cold | Boiler runs but the house stays cold | Pump fault, air or sludge blocking circulation | Engineer |
| Hot water pipe stays cold | Heating works, taps run cold | Diverter valve or plate heat exchanger | Gas Safe engineer |
Stay safe around boiler pipework
- Never touch, loosen or adjust the gas pipe or gas valve. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance and its gas supply.
- Do not remove the boiler casing to look at pipes or connections inside it.
- Do not block, cap or shorten the relief valve pipe outside, even if it drips. It is a safety device.
- Pipes under the boiler can be hot enough to burn.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn off the gas at the meter if it is safe to do so.
Do you need new pipework for a new combi?
It depends on what you have now.
- Combi to combi in the same place. The existing pipes can often be reused with small changes, because new boilers rarely have their connections in exactly the same positions as old ones. The gas pipe may need upsizing if the new boiler needs more gas than the old one, and a poor condensate run should be upgraded.
- Regular or system boiler to combi. The hot water cylinder, loft tanks and their pipework come out, and the hot and cold pipes are reworked to run straight from the combi.
- Moving the boiler. Every pipe has to be extended or rerun to the new position, including the gas, flue and condensate.
The installer’s survey should check all of this before the price is fixed. Our boiler installation page explains how we survey a new boiler.
What it costs with Vantage
In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
Frequently asked questions
How many pipes are connected to a combi boiler?
Usually seven: five main pipes (gas, heating flow, heating return, cold mains in and hot water out) plus the pressure relief valve discharge pipe and the condensate pipe. Some boilers also have a filling loop connected between the cold mains and the heating side.
Which pipe is the cold water inlet on a combi boiler?
It is the 15mm pipe that stays cold, usually with an isolating valve that has a blue handle or marking. The exact position varies between makes, so check the connection diagram in your boiler’s manual.
Why is the copper pipe outside my boiler dripping?
That is the pressure relief valve discharge pipe. If it drips, the valve has opened, usually because the system pressure has gone too high. Check the gauge and book an engineer, because the cause is usually the expansion vessel, the filling loop or the valve itself.
What size gas pipe does a combi boiler need?
It depends on the boiler’s gas rate and the length and route of the pipe from the meter. The connection on the boiler is 15mm on some models and 22mm on others, and the supply pipe from the meter is often 22mm or larger. A Gas Safe engineer sizes it and checks the pressure when the boiler is fitted.
Can I move the pipes under my boiler myself?
The water pipes are plumbing, but they connect to a gas appliance and a sealed system, and any mistake can stop the boiler or cause a leak. The gas pipe must only be worked on by a Gas Safe registered engineer.
When to call an engineer
If a pipe under your boiler is leaking, the relief valve pipe outside is dripping, or the pressure keeps rising or falling, it is time for an engineer. We are Gas Safe registered (956889), based in Stevenage and working across Hertfordshire, Bedfordshire and Cambridgeshire. Book through our boiler repair page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374