Does Gas Central Heating Work in a Power Cut?
Hertfordshire, Bedfordshire & Cambridgeshire
No, gas central heating does not work in a power cut in almost every UK home. Even though gas keeps flowing to the house, a modern gas boiler needs electricity for its controls, ignition, fan and pump, so it stops when the power goes and should restart on its own once the supply comes back.
- A gas boiler needs electricity to light, to run its fan and to pump water round the radiators.
- The gas supply normally carries on during a power cut, so a gas hob may still work.
- Combi boilers give no hot water in a power cut. A hot water cylinder keeps its stored hot water for a while.
- Never use a barbecue, patio heater, camping stove or generator indoors to keep warm.
- If the boiler does not restart when the power returns, check the display, the timer, the pressure and the fused spur before calling an engineer.
New boiler?
Get an instant estimate for a new boiler
Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.
Why a gas boiler needs electricity
A modern boiler is controlled by electronics from start to finish. Gas is the fuel, but electricity runs almost everything around it.
| Part | What it does | Needs electricity? |
|---|---|---|
| Circuit board (PCB) | Controls the whole boiler and its safety checks | Yes |
| Fan | Pulls in air and pushes flue gases out | Yes |
| Ignition | Creates the spark that lights the burner | Yes |
| Gas valve | Opens only when the controls say it is safe | Yes |
| Pump | Moves hot water around the radiators and cylinder | Yes |
| Thermostat, timer and smart controls | Tell the boiler when to fire | Most need mains power, some wireless ones need it at the receiver |
| Diverter or zone valves | Send heat to the radiators or the hot water | Yes |
Because the gas valve is held closed unless the electronics open it, a boiler cannot light itself during a power cut. That is a safety feature, not a fault, and every modern gas system works this way, including the ones we fit through our central heating installation service.
Are there any exceptions?
A few very old systems with a permanent pilot light and a gravity-fed hot water circuit could keep warming the hot water cylinder without power, because gravity moves the water rather than a pump. The radiators still would not heat, because they rely on the pump. These systems are now rare. If you have a modern combi, system or regular boiler, assume it will not run.
What still works in a power cut
- The gas supply. Gas usually keeps flowing to the house, because the gas network does not depend on your electricity supply.
- A gas hob. Many gas hobs can be lit carefully with a match if the electric ignition is not working. Check your hob’s instructions first, because some models will not work without power.
- Stored hot water. If you have a hot water cylinder, the water inside stays hot for some hours, depending on how well the cylinder is insulated. Use it sparingly.
- Some gas fires. A gas fire with battery or push-button ignition and no fan may still work. Only use it if it has been serviced, and make sure the room has the ventilation the fire needs.
A combi boiler heats water only as you use it, so with a combi you will have no hot water until the power returns. Your cold water will normally keep running, because mains water pressure does not depend on your electricity, unless your home relies on a booster pump.
How to stay warm safely
- Keep the heat in. Close curtains and blinds, shut internal doors and use draught excluders. Gather everyone in one room.
- Dress in layers. Several thin layers keep you warmer than one thick one, and a hat helps.
- Use stored hot water wisely. A cylinder of hot water can fill hot water bottles for a while.
- Eat and drink something warm if you can heat it safely on a gas hob.
- Check on neighbours, especially older people and anyone with young children.
Carbon monoxide danger
- Never use a barbecue, patio heater, camping stove, paraffin heater or generator indoors, in a garage or near an open window. They produce carbon monoxide, which can kill.
- Never use a gas oven or hob to heat the room.
- Make sure your carbon monoxide alarm has working batteries, because a mains alarm without battery backup will not work during a power cut.
- If you smell gas, open windows, do not use electrical switches, turn off the gas at the meter if it is safe to do so and call the National Gas Emergency Service on 0800 111 999.
Reporting a power cut
Call 105 to report a power cut or damage to power lines. It is free from most landlines and mobiles in England, Scotland and Wales and puts you through to the electricity network operator for your area. If someone in your home is older, disabled, has a young child or relies on medical equipment, ask your energy supplier and network operator about the Priority Services Register, which can mean extra support during a power cut.
When the power comes back: if the boiler will not restart
Most boilers restart on their own. If yours does not, work through these checks in order.
- Look at the display. Note any fault code or flashing light. Some boilers lock out if the power dropped while they were running.
- Check the fused spur. The switched fused spur next to the boiler should be on. Also check the consumer unit, because a power surge when the supply returns can trip a breaker or RCD.
- Reset the clock and timer. Mechanical timers and some programmers lose their time in a power cut, so the heating may be set to come on at the wrong time.
- Check the thermostat. Wireless thermostats may need new batteries or re-pairing with the boiler.
- Check the pressure. It should usually be around 1 to 1.5 bar cold on most sealed systems. If it is low, top it up following your boiler’s user guide.
- Check the condensate pipe if the weather is freezing, because a boiler that has been off for hours can have a frozen pipe. Thaw it with warm, not boiling, water.
- Press reset once or twice. If it will not restart after two or three tries, stop and call a Gas Safe engineer.
Our guide to a boiler not firing up goes through these checks in more detail, and our broken boiler checklist covers what to do first when the heating fails.
Can a power cut damage a boiler?
Occasionally. A surge or spike when the supply returns can damage a circuit board or a control. If the boiler shows no signs of life at all, but the fused spur and consumer unit are on, the problem may be electrical inside the boiler. That needs a Gas Safe registered engineer through our boiler repair service.
Keeping the heating on during power cuts
If you live somewhere with frequent power cuts, there are ways to keep a boiler running.
- Battery backup units designed for boilers can run the boiler and pump for a limited time.
- A generator can run a boiler, but it must be connected through a proper changeover switch installed by a qualified electrician. Never plug a boiler into a generator with an adaptor or extension lead, and never run a generator indoors.
- A standby heat source, such as a solid fuel stove or a gas fire that does not need electricity, gives you a warm room but not full heating.
Check your boiler manufacturer’s instructions before connecting any backup supply, because some boilers need a stable, earthed supply to work properly. If you are replacing an old heating system, we can talk through the controls and backup options that suit your home.
What it costs with Vantage
In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
Frequently asked questions
Does a combi boiler work without electricity?
No. A combi needs electricity for its controls, fan, ignition and pump, so it gives neither heating nor hot water during a power cut. It should restart when the power returns.
Is it safe to leave the boiler switched on during a power cut?
Yes. The boiler simply stops, and its gas valve stays closed without power. When the supply returns it will normally restart by itself. You do not need to turn off the gas.
Can I use my gas hob in a power cut?
Often, yes. Many gas hobs can be lit carefully with a match if the electric ignition does not work, but check the manufacturer’s instructions first. Never use the hob or oven to heat the room.
Why is my boiler not working after a power cut?
The most common reasons are a timer that has lost its settings, a tripped fused spur or breaker, a boiler in lockout, low pressure or a frozen condensate pipe. If none of those is the cause, a surge may have damaged a control and an engineer should check it.
How long will my hot water last in a power cut?
A well-insulated hot water cylinder can keep water usefully warm for some hours, sometimes longer. A combi boiler stores no hot water, so you will have none until the power comes back.
Heating help in Hertfordshire, Bedfordshire and Cambridgeshire
If your boiler will not come back on after a power cut, our Gas Safe registered engineers can find out why. The phone is answered 24 hours a day, 7 days a week, and we offer 24/7 emergency cover. See our boiler repair page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374