Skip to main content

Vantage Plumbing and Heating

Do You Need a New Gas Pipe for a New Boiler?

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

You do not always need a new gas pipe for a new boiler, but you often do when you switch to a combi, move the boiler, or add a bigger boiler, because the existing pipe may be too small to deliver enough gas. The Gas Safe engineer decides by working out the boiler’s gas demand, the length and route of the pipe from the meter and the other gas appliances in the house, then checking the gas pressure at the boiler once it runs.

  • Gas pipes are sized so that no more than 1 mbar of pressure is lost between the meter and the appliance on natural gas, under BS 6891.
  • Combi boilers use gas at a high rate when heating hot water, so a pipe that suited an old regular boiler can be too small.
  • Moving the boiler to a new position almost always means new gas pipework.
  • The boiler’s own gas connection can be smaller than the pipe that feeds it. The supply from the meter is sized separately.
  • An undersized pipe can cause ignition faults, lockouts and poor hot water, especially when the hob is on.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

Why the gas pipe size matters

Your gas meter delivers gas at a set pressure. As gas travels along the pipe to the boiler, it loses a little pressure through friction, and every bend, tee and extra metre adds to that loss. The more gas the boiler draws at once, the bigger the loss.

The British Standard for domestic gas pipework, BS 6891, allows a maximum pressure loss of 1 mbar between the meter outlet and the appliance inlet on natural gas, with every appliance on that pipe running. If the pipe is too small or too long, the boiler does not get enough pressure at its inlet. It may still light, but it can struggle at full output, lock out or fail to light at all.

Boiler manufacturers also set their own requirements. For example, the installation manual for a current Glow-worm combi tells the installer to make sure the existing gas meter can pass the gas rate required, and to check the gas inlet working pressure with the boiler running at full load. Other makers have similar instructions.

Our boiler installation engineers check this on every survey, because it is one of the details that separates a boiler that works well from one that keeps faulting.

When you are likely to need a new gas pipe

SituationNew pipe likely?Why
Like-for-like combi swap in the same placeSometimesOnly if the old pipe was undersized or fails the checks
Regular or system boiler replaced with a combiOftenA combi’s hot water demand needs a much higher gas rate
Back boiler replaced with a wall-hung boilerAlmost alwaysThe boiler moves and the old supply rarely suits
Boiler moved to a new room or wallYes, for the new sectionThe route changes and gets longer
Higher output boiler fittedOftenMore gas demand through the same pipe
Extra gas appliances added, such as a range cookerPossiblyThe pipe must cope with everything running at once
Old, damaged or corroded pipeYesSafety comes first, whatever its size

Why combis often need a bigger pipe

A combi boiler heats hot water instantly as it flows through, rather than storing it in a cylinder. To do that, it burns gas at a high rate whenever a hot tap is open. That hot water output is usually much higher than the heating output of the regular boiler it replaces.

A pipe that coped perfectly well with an older boiler and a hob can then be too small. It is common for the pipe from the meter to the boiler to need upsizing when a house moves to a combi, particularly where the meter is at the far end of the house from the boiler, or the pipe runs up through several floors.

Our guide to the best combi boilers covers the output sizes available.

The boiler connection is not the pipe size

Many people look at the boiler and see a small gas pipe coming out of the bottom, and assume that is the pipe size they need. The connection on the boiler itself can be quite small. The Glow-worm manual mentioned above, for instance, gives a half-inch gas connection on the boiler. What matters is the size of the pipe that runs from the meter to the boiler, which is chosen for the boiler’s gas rate and the length of the run. That supply is often larger than the boiler’s own connection, and reduces down at the boiler.

How a Gas Safe engineer decides

A proper assessment goes something like this:

  1. Identify all the gas appliances. The boiler, hob, oven, gas fire and anything else on the supply.
  2. Find the gas rate of each. The boiler’s maximum gas rate comes from the manufacturer’s data.
  3. Measure the pipe run. The engineer measures each section of pipe from the meter, and allows for the bends, elbows and tees, which add resistance.
  4. Calculate the pressure loss. Using the standard’s method, the engineer works out whether each section can carry its share of the gas within the 1 mbar limit.
  5. Check the meter. The meter must be able to pass the total gas rate of all the appliances.
  6. Test on commissioning. Once the boiler is fitted, the engineer carries out a gas tightness test, then checks the working pressure at the boiler with it running at full load, and ideally with other appliances on too.

If the calculation shows the existing pipe is too small, part or all of the run will be replaced with a larger one.

Signs your gas pipe may be too small

If you already have a new boiler and notice these, the gas supply is worth checking:

  • The boiler locks out or shows an ignition fault, especially when you run a hot tap.
  • Hot water is weaker than expected, or the temperature drops when the hob is on.
  • The hob flames drop noticeably when the boiler fires up.
  • Faults such as a failed ignition code appear more often in the evening, when more appliances are running.

On many boilers, a gas supply problem shows up as a failed ignition code. Our guides to the Vaillant F28 fault code and Worcester Bosch EA fault code explain those.

Safety

  • Only a Gas Safe registered engineer may alter, extend or replace gas pipework. This is the law under the Gas Safety (Installation and Use) Regulations 1998.
  • Do not try to connect, disconnect or move any gas pipe yourself, even if it looks simple.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches and turn the gas off at the meter if it is safe to do so.
  • You can check any engineer on the Gas Safe Register.

Where the new pipe will run

When new gas pipework is needed, the engineer plans the route to be safe, accessible and as short as practical. Good practice includes:

  • Keeping the run as direct as possible, with as few bends as sensible.
  • Sleeving the pipe where it passes through walls.
  • Supporting the pipe properly with clips at the right spacing.
  • Protecting pipes run in floors or buried in walls, and not running them inside a wall cavity.
  • Keeping gas pipes clear of electrical cables and other services.

In many homes, the new pipe can run along the outside wall, through a garage, or under the floor. Your installer should show you the planned route at the survey, because it affects where boxing-in or making good is needed.

Mistakes to avoid

  • Assuming a like-for-like boiler means like-for-like pipe. If the old boiler was a different type, or the pipe was undersized all along, it may not be enough.
  • Choosing a quote that ignores the gas supply. A good quote says whether the gas pipe is being upgraded and why. Our guide on how to choose a boiler installer covers what to look for.
  • Moving the boiler without thinking about the route. A new position can mean a long pipe run and more making good.
  • Oversizing the boiler. A boiler with a higher output than you need uses more gas at full rate and puts more demand on the pipe.

How we price it

Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. The survey includes checking whether your gas pipe is big enough, and any upgrade is shown in the quote before you agree to anything. You can get your price online in a couple of minutes with our boiler quote tool. Our new boiler packages include a magnetic system filter, the first year’s service and removal of the old boiler, and our work comes with a 12 month labour guarantee. Our repair rates are on our prices page.

Frequently asked questions

What size gas pipe does a combi boiler need?

There is no single answer, because it depends on the boiler’s gas rate, the length of the pipe from the meter, the number of bends and the other appliances on the supply. The pipe from the meter is often larger than the boiler’s own connection. A Gas Safe engineer calculates it to BS 6891.

Can I reuse my old gas pipe with a new boiler?

Often you can, if it is in good condition, correctly supported and big enough for the new boiler’s gas rate. The engineer checks all of that during the survey and confirms it with a pressure test when the boiler is commissioned.

Does a new gas pipe mean lifting floors?

Not always. Many new gas runs go along an outside wall, through a garage or loft, or follow the route of the old pipe. Where floors have to be lifted, the installer should agree that with you before starting.

Who can install a gas pipe for a boiler?

Only a Gas Safe registered engineer can legally install or alter gas pipework. Check their Gas Safe ID card and the categories they are qualified for. Our Gas Safe registration number is 956889.

Will an undersized gas pipe damage my boiler?

It can cause poor performance, lockouts and ignition faults, and it means the boiler is not running as its manufacturer intended. It should be corrected rather than lived with.

Boiler installation in Hertfordshire, Bedfordshire and Cambridgeshire

If you are planning a new boiler, we will check the gas supply as part of a free survey and tell you plainly whether the pipe needs upgrading. See our boiler installation page, get a price with our boiler quote tool, or call 01462 506374. We are rated 4.9 on Google.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.