Heat Loss Calculations Explained: Formula, Example and Why It Matters

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

A heat loss calculation works out how much heat, in watts, each room and the whole house loses on a cold day, so the boiler, heat pump and radiators can be sized to replace it. It adds up the heat lost through the walls, windows, floor and roof (area times U-value times the temperature difference) plus the heat lost through ventilation, room by room.

In short

  • Heat loss is measured in watts at a design temperature difference between inside and outside.
  • Fabric heat loss = U-value x area x temperature difference, for every wall, window, floor and ceiling.
  • Ventilation heat loss = 0.33 x air changes per hour x room volume x temperature difference.
  • A room-by-room calculation sizes each radiator; the total guides the boiler or heat pump size.
  • Heat pump installations under MCS need a room-by-room heat loss calculation, and it is good practice for boilers too.

What is a heat loss calculation?

Your home is always losing heat to the outside. The colder it is outside, the faster it loses heat. A heat loss calculation estimates that rate on a cold winter’s day, which heating designers call the design condition.

The result is a figure in watts (or kilowatts) for each room and for the whole house. It tells you three things:

  1. How big each radiator or heat emitter needs to be so that every room reaches its target temperature.
  2. How much heat the boiler or heat pump needs to provide for space heating.
  3. Where the heat is going, which shows where insulation or draught-proofing would help most.

It is the foundation of any proper central heating installation. Without one, sizing is guesswork, usually based on the old boiler, the number of radiators or a rule of thumb.

The two parts of heat loss

Fabric heat loss

This is heat conducted through the building fabric: walls, windows, doors, floors and roofs. Each element has a U-value, which is how many watts pass through one square metre for each degree of temperature difference. A lower U-value means better insulation.

Fabric heat loss (watts) = U-value x area (m²) x temperature difference (°C)

You work this out for every surface of a room that faces somewhere colder: outside, an unheated loft, a garage or the ground.

Ventilation heat loss

Warm air leaks out through gaps, vents, chimneys and open doors, and cold air replaces it. The standard formula is:

Ventilation heat loss (watts) = 0.33 x air changes per hour x room volume (m³) x temperature difference (°C)

The 0.33 reflects how much heat air holds. The air change rate is how many times the room’s full volume of air is replaced each hour. Older, draughty homes and rooms with open chimneys have higher rates; modern, well sealed homes have lower ones.

Putting it together

Total room heat loss = fabric heat loss + ventilation heat loss.

These are the methods set out in the Open University’s building energy course and used, in more detail, in BS EN 12831 and the CIBSE Domestic Heating Design Guide, which heating engineers and heat pump designers work to.

The inputs you need

InputWhat it isWhere it comes from
Room dimensionsLength, width and height of each roomMeasured on survey
Wall, window, floor and roof areasEach surface facing somewhere colderMeasured on survey
U-valuesHeat loss rate of each constructionConstruction type, age, insulation, standard tables
Indoor design temperatureThe target for each roomTypically around 21°C for living rooms and 18°C for bedrooms, with bathrooms set warmer
Outdoor design temperatureA cold-day figure for your locationStandard tables used by MCS and CIBSE
Air change rateHow leaky each room isRoom type, age of property, chimneys
Adjacent spacesHeated or unheated rooms next door, above and belowSurvey

The U-values are where most errors creep in. A solid brick wall, an empty cavity wall and a filled cavity wall behave very differently. Standard tables have also been revised as better data became available. For example, Scottish Government research on energy certificates notes that measured U-values of solid brick walls in real homes were often lower (better) than the older default value of 2.1 used in assessments, which led to the defaults being reduced. Using out-of-date defaults tends to overestimate heat loss.

A worked example: one bedroom

Here is a simple example to show how the numbers come together. The U-values are assumed values for illustration, not figures for your home.

A bedroom measures 3.5m by 3.0m with a 2.4m ceiling. It has one external wall with a window, an insulated loft above and heated rooms below and on the other sides. The target is 18°C and we assume an outdoor design temperature of minus 2°C, a difference of 20°C.

ElementAreaAssumed U-valueHeat loss
External wall (unfilled cavity)8.4m² minus 1.5m² window = 6.9m²1.56.9 x 1.5 x 20 = 207W
Window (older double glazing)1.5m²2.81.5 x 2.8 x 20 = 84W
Ceiling to insulated loft10.5m²0.310.5 x 0.3 x 20 = 63W
Ventilation (1 air change an hour)25.2m³0.33 x 10.33 x 1 x 25.2 x 20 = 166W
Totalabout 520W

So this room needs a radiator that gives out around 520W at the water temperature the system runs at. Fill that cavity wall and the wall loss would drop sharply, which would allow a smaller radiator or a lower flow temperature.

Repeat that for every room, add the results together and you have the design heat loss for the house.

Why it matters for boilers

For a system or regular boiler, the heat loss figure (plus an allowance for heating a hot water cylinder) guides the output needed. Many homes have boilers far bigger than their heat loss because the replacement simply matched the old one.

For a combi boiler, the size is mostly decided by hot water demand, because heating tap water instantly takes more power than heating most houses. The heat loss still matters, because a combi that can turn down low enough to match a small heat loss will cycle less and run more efficiently. Our guide to the best combi boilers explains how we size combis on hot water.

Why it matters for radiators

Radiator outputs in catalogues are usually quoted at a temperature difference called Delta T 50, which assumes quite hot water. Modern condensing boilers work most efficiently with cooler water returning to them, and at lower flow temperatures a radiator gives out noticeably less heat. At the much lower temperatures a heat pump runs at, a radiator can give out roughly half of its Delta T 50 rating or less.

A room-by-room heat loss calculation lets an engineer check that each radiator is big enough at the flow temperature you want to run. If a room never gets warm, it may be an undersized radiator rather than a fault. Our guide to a radiator not heating up covers the other causes to check first.

Why it matters for heat pumps

Heat pumps are much less forgiving of poor sizing than gas boilers. They run at lower water temperatures, so the radiators must be sized correctly, and an oversized heat pump costs more and can run less efficiently. That is why heat pump installations certified under MCS need a room-by-room heat loss calculation, and the Energy Saving Trust’s installer guidance covers it in detail.

Online calculators or a proper survey?

Online heat loss calculators from radiator makers and merchants are useful for a rough radiator size in one room. They cannot see your walls, measure your windows or check whether a cavity is filled.

MethodGood forLimits
Online calculatorA quick radiator size for one roomRelies on your guesses about construction and U-values
Rule of thumb (watts per square metre)Very rough budgetingIgnores insulation, glazing and exposure
Room-by-room survey calculationBoiler, heat pump and radiator sizingTakes time and needs accurate measurements

Common mistakes

  • Sizing on the old boiler. The old one was often oversized to start with.
  • Using worst-case U-values. Guessing every wall is uninsulated inflates the result.
  • Ignoring ventilation. Open chimneys and draughty rooms can lose a lot of heat through air leakage.
  • Forgetting the rooms next door. A room next to an unheated garage or conservatory loses more heat than one next to a heated room.
  • Adding big safety margins on every line. They add up to a system that is far larger than needed.

How we price it

Heating installations, including new boilers, radiator upgrades and full central heating systems, are quoted as a fixed price after a free survey, so the price you agree is the price you pay. For a new boiler, you can get your price online in a couple of minutes with our boiler quote tool. Repair and servicing rates are published on our prices page.

Frequently asked questions

What is the formula for heat loss?

For each surface, heat loss equals U-value times area times the temperature difference between inside and outside. For air leakage, it is 0.33 times the air changes per hour times the room volume times the temperature difference. Add both together for each room.

How do I calculate heat loss for an extension?

Measure the new walls, windows, roof and floor, apply the U-values from the building control drawings (new extensions have to meet current insulation standards) and add the ventilation loss. The result tells you what size radiator or underfloor heating the extension needs and whether the existing boiler can cope.

Do I need a heat loss calculation for a new boiler?

It is not always carried out for a like-for-like combi swap, but it is good practice and it avoids an oversized boiler. It is essential when changing to a system boiler, adding rooms or radiators, or lowering flow temperatures.

What is a good heat loss figure for a house?

There is no single good figure, because it depends on size, age and construction. A useful measure is watts per square metre of floor area: lower is better, and insulation, glazing and draught-proofing are what bring it down.

Is heat loss the same as the boiler size?

No. Heat loss is what the house needs on a cold day for heating. A combi boiler is usually larger because it is sized for instant hot water, and a system boiler may include an allowance for heating the cylinder.

Help with heating design in Hertfordshire, Bedfordshire and Cambridgeshire

If you are replacing a boiler, adding radiators or planning a new heating system, we will survey the house and size everything properly. See our central heating installation page or call 01462 506374, answered 24 hours a day, 7 days a week.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.