How Does a Boiler Work? A Plain-English Guide
Hertfordshire, Bedfordshire & Cambridgeshire
A boiler burns gas (or oil) in a sealed combustion chamber and passes the heat through a heat exchanger into water, which a pump then sends around your radiators or, for hot taps, either heats instantly (a combi) or stores in a cylinder (a system or regular boiler). A modern condensing boiler also captures extra heat from its exhaust gases, which is why it has a plastic condensate pipe running to a drain.
In short
- Gas and air mix at the burner, a spark lights them and a sensor confirms the flame.
- The flame heats water passing through the heat exchanger, and the pump sends it round the radiators.
- A combi heats tap water on demand; system and regular boilers heat a stored cylinder.
- Condensing boilers recover heat from the flue gases, producing mildly acidic water that drains away.
- A circuit board runs the whole sequence and shuts the boiler down safely if anything is wrong.

The basic idea
Every gas boiler does the same job: it turns the energy in gas into hot water. That hot water is used in two ways. It flows around a closed loop of pipes and radiators to heat the house, and it heats the water that comes out of your taps and shower.
The water in the radiators and the water from your taps are kept separate. The radiator water, called the primary circuit, goes round and round and is treated with inhibitor to protect the metal. The tap water, called domestic hot water, is fresh water that is heated and then used.
If you are thinking about a new boiler installation, understanding the parts below makes it much easier to compare boilers and quotes.
What happens when you turn the heating on
- A demand is sent. Your thermostat or programmer tells the boiler that the house needs heat, or you open a hot tap on a combi.
- The fan starts. It draws in fresh air and clears the combustion chamber, and the boiler checks that air is moving properly.
- The gas valve opens and lets a measured amount of gas into the burner, where it mixes with the air.
- The spark ignites it. An ignition electrode sparks, and a flame sensor confirms that a flame has lit. If it does not detect a flame, the boiler shuts the gas off and, after a few tries, shows a fault code.
- The heat exchanger heats the water. Water from the primary circuit passes through the heat exchanger, a metal block of channels that sits in the heat of the flame.
- The pump circulates it around the radiators and back to the boiler.
- The flue removes the exhaust gases safely outside.
- The boiler modulates. As the house warms up, it turns the flame down to match the heat needed, and switches off when the thermostat is satisfied.
If a boiler will not start at step 3 or 4, our guide to a boiler not firing up explains the usual causes.
The main parts of a boiler
| Part | What it does |
|---|---|
| Gas valve | Controls how much gas goes to the burner, and shuts it off instantly if there is a problem |
| Fan | Supplies air for combustion and pushes the exhaust gases out through the flue |
| Burner and ignition electrode | Where gas and air mix and are lit |
| Flame sensor | Confirms there is a flame, so gas is never released without one |
| Heat exchanger | Transfers heat from the flame into the water |
| Pump | Moves water around the heating system |
| Expansion vessel | Absorbs the expansion of water as it heats up, in sealed systems |
| Pressure relief valve and gauge | Protect the system from too much pressure and show you the current pressure |
| Diverter valve (combis) | Switches the hot water between the radiators and the taps |
| Plate heat exchanger (combis) | Heats the mains water for your taps using the hot primary water |
| Printed circuit board (PCB) | The boiler’s brain, running the sequence and safety checks |
| Flue | Takes combustion gases safely outside |
| Condensate trap and pipe | Collects and drains the water produced by condensing |
How a condensing boiler gets its efficiency
Older boilers sent a lot of heat straight out of the flue as hot exhaust gases. A condensing boiler has a larger or second stage of heat exchanger that cools those gases down. When they cool enough, the water vapour in them condenses back into water, releasing extra heat that goes into your heating.
The Energy Saving Trust explains that condensing boilers are more efficient because they capture and reuse more of the heat that would otherwise escape through the flue, and that a gas boiler installed after 2005 should be a condensing model. Manufacturers such as Vaillant describe modern boilers as more than 90% efficient.
There is one catch. The boiler only condenses well when the water coming back from the radiators is cool enough, generally around 55°C or below. If the boiler is set to send out very hot water all the time, it may rarely condense. Setting a sensible flow temperature, having correctly sized radiators and using good controls all help.
The condensate is mildly acidic, which is why it runs through a plastic pipe to a drain rather than into metal pipework. In freezing weather, an outside condensate pipe can freeze and stop the boiler. Our guide to a frozen condensate pipe shows how to thaw it safely with warm water.
Combi, system and regular boilers
The way the boiler heats hot water is the main difference between the three types.
| Combi | System | Regular (heat only) | |
|---|---|---|---|
| Hot water | Heated instantly from the mains when you open a tap | Stored in a cylinder heated by the boiler | Stored in a cylinder heated by the boiler |
| Tanks in the loft | None | None | Cold water tank and a small feed and expansion tank |
| Cylinder | None | Yes, often unvented | Yes, usually vented |
| Pump and expansion | Pump and expansion vessel built in | Pump and expansion vessel built in | Pump usually separate; expansion goes to the loft tank |
| Best for | Most homes with one bathroom | Homes with two or more bathrooms used at once | Homes with an existing tank-fed system, or low mains pressure |
How a combi heats tap water: when you open a hot tap, a flow sensor detects the water moving and the diverter valve switches the boiler’s hot primary water from the radiators to the plate heat exchanger. The mains water passing the other side of the plate heats up instantly. That is why a combi pauses the heating while you run a shower, and why its hot water flow rate matters so much. Combis are sized on hot water flow rather than on the number of radiators.
How system and regular boilers heat water: the boiler heats water in a coil inside the hot water cylinder. A motorised valve, controlled by the programmer and a thermostat on the cylinder, decides whether the boiler’s heat goes to the cylinder, the radiators or both. The stored water is then ready for several taps at once.
Sealed systems and water pressure
Combi and system boilers usually run on a sealed system. It is filled from the mains through a filling loop to a set pressure, and the expansion vessel absorbs the water’s expansion as it heats. Most boiler user guides give a normal cold pressure of around 1 to 1.5 bar. If the pressure keeps dropping, water is escaping somewhere, which our guide on a boiler that keeps losing pressure explains.
Regular boilers on a vented system are fed from a tank in the loft instead, so they have no pressure gauge to top up.
What about oil boilers?
Oil boilers work in a very similar way. A pump sprays a fine mist of oil into the burner, where it is lit and heats a heat exchanger. The heat is used exactly as with a gas boiler, and oil boilers can be combi, system or regular too. We repair and service oil boilers as well as gas.
Safety features built in
- Flame supervision: gas cannot flow without a confirmed flame.
- Overheat thermostat: shuts the boiler down if the water gets too hot.
- Pressure relief valve: releases water safely if the pressure gets too high.
- Air and flue monitoring: the boiler checks the fan and flue are working before it lights.
- Fault codes: when a check fails, the boiler locks out and shows a code instead of carrying on.
What you can and cannot do
- You can check the pressure gauge, top up with the filling loop if the user guide allows it, bleed radiators, press reset a small number of times and thaw a frozen condensate pipe with warm, not boiling, water.
- Never remove the casing or touch the gas valve, fan, PCB, heat exchanger or flue. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches and turn off the gas at the meter if it is safe.
Keeping a boiler working well
- Have it serviced every year. A boiler service checks combustion, cleans what needs cleaning and keeps most guarantees valid.
- Fit a magnetic filter to catch sludge before it reaches the heat exchanger. Every Vantage boiler package includes one.
- Keep the inhibitor topped up in the heating water.
- Use good controls, so the boiler only runs when and as hard as it needs to.
How we price it
Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. You can get your price online in a couple of minutes with our boiler quote tool. New boiler packages include a magnetic system filter, the first year’s service and removal of the old boiler. Repair and servicing rates are published on our prices page.
Frequently asked questions
How does a combi boiler heat water so quickly?
It uses a plate heat exchanger. When you open a hot tap, the boiler switches its hot primary water to one side of the plate, and the mains water flowing through the other side heats up as it passes. Nothing is stored, so the flow rate is limited by the boiler’s output.
Why does my boiler have a pipe dripping water outside?
That is the condensate pipe. Condensing boilers produce water when they cool their exhaust gases, and it drains away through this pipe. It is normal to see some water, and in freezing weather the pipe can freeze and stop the boiler.
Does a boiler heat water all the time?
No. It only fires when the thermostat, programmer or a hot tap asks for heat, and it turns its flame down as it gets close to the target temperature. A system or regular boiler also heats the cylinder only when the cylinder thermostat calls for it.
What is the difference between a boiler and a heat pump?
A boiler burns fuel to make heat, while a heat pump uses electricity to move heat from the outside air or ground into the house. Heat pumps run at lower water temperatures, so they usually need larger radiators than a boiler.
How long does a boiler last?
It depends on the quality of the installation, the water in the system and servicing. Rising repair bills, repeat faults and a system full of sludge are the usual signs that a replacement is due.
Boiler help in Hertfordshire, Bedfordshire and Cambridgeshire
Whether your boiler needs a repair or you are ready for a new one, we can help. See our boiler installation page or call 01462 506374, answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.