How Much Can a New Boiler Save You? The Honest Answer
Hertfordshire, Bedfordshire & Cambridgeshire
Replacing an old non-condensing boiler with a modern condensing boiler can cut the gas you use for heating and hot water by roughly a quarter to a third, because an old boiler loses far more heat up the flue. If your current boiler is already a condensing model from the last 15 years or so, the saving from the boiler alone is much smaller, often under a tenth, and better controls and lower flow temperatures matter as much as the boiler itself.
- The saving depends mainly on how efficient your old boiler is, not how good the new one is.
- Old non-condensing boilers can be well under 80% efficient. New gas boilers in England must be at least 92% (ErP).
- Swapping one condensing boiler for another saves far less than replacing a non-condensing one.
- Controls, a clean system and a lower flow temperature add to the saving.
- Reliability, safety and fewer repairs are often as important as the fuel saving.

Why a new boiler uses less gas
A boiler burns gas to heat water. Some of the heat from the flame always escapes up the flue in the hot exhaust gases. An old non-condensing boiler lets a lot of that heat go. A condensing boiler has a larger heat exchanger that cools the flue gases enough for the water vapour in them to condense, and it recovers heat from that process. The Energy Saving Trust explains that modern condensing boilers are more efficient because they capture and reuse more of the heat that would otherwise escape.
Since 2005, almost all new gas boilers fitted in England and Wales have had to be condensing. In England, the Boiler Plus standard also requires a new gas boiler to have an ErP efficiency of at least 92%, with time and temperature controls. So the question is really how far your current boiler falls short of that. If you are thinking about a replacement, our boiler installation page explains how we survey and specify a new boiler.
Work out your likely saving
The simplest way to estimate the saving is to compare the efficiency of your old boiler with the new one. If a boiler is 70% efficient, it needs 100 units of gas to deliver 70 units of heat. A boiler working at 92% needs about 76 units of gas for the same 70 units of heat, which is roughly 24% less gas.
| Old boiler efficiency | Gas a 92% boiler needs for the same heat | Reduction in gas used |
|---|---|---|
| 60% (very old, non-condensing) | About 65% of what you use now | About 35% less |
| 70% (older non-condensing) | About 76% of what you use now | About 24% less |
| 78% (late non-condensing) | About 85% of what you use now | About 15% less |
| 86% (early or tired condensing) | About 93% of what you use now | About 7% less |
These figures are simple arithmetic based on rated efficiencies. Real-world savings depend on how the new boiler is set up and used, as explained below. For oil, OFTEC says older appliances typically run at around 60 to 70% efficiency and that condensing equipment could save up to 30% on fuel, which fits the same pattern.
How to apply it to your own bill
- Find your annual gas use in kWh on your energy bill or supplier app.
- Estimate your current boiler’s efficiency. The model name and age are the best guide: a boiler with no condensate pipe running to a drain is almost certainly non-condensing.
- Multiply your annual gas use by the reduction in the table.
- Remember that gas used for cooking is not affected, so the saving applies to heating and hot water only.
Where the rest of the saving comes from
A new boiler only gets close to its rated efficiency if it condenses most of the time. That depends on how the system is run, not just on the boiler.
- Lower flow temperature. A condensing boiler is more efficient when the water returning from the radiators is cooler. The Energy Saving Trust cites research from Nesta showing that turning the flow temperature down to 60 degrees improves boiler efficiency by nearly 4%.
- Better controls. A programmer, room thermostat and thermostatic radiator valves stop the boiler heating an empty or already warm home. The Energy Saving Trust notes that upgrading from a G-rated boiler with no controls to an A-rated boiler with full controls can make a big difference to running costs and your EPC.
- Weather or load compensation. These let the boiler lower its flow temperature when full output is not needed. A new combi in England must have at least one extra energy saving measure, and a smart thermostat with automation and optimisation is one of the options.
- A clean system. Sludge makes the boiler and radiators work harder. A new boiler should be fitted after the system is cleaned and flushed, with inhibitor added, and a magnetic filter to catch debris. On a badly sludged system, a power flush may be the right first step.
- The right size. An oversized boiler cycles on and off more often. A proper heat loss calculation matters more than choosing the biggest output.
When a new boiler will not save much
Be wary of anyone promising large savings without asking about your current boiler. You are unlikely to see a big drop in gas use if:
- your boiler is already a condensing model that is working well and serviced
- your home is small or well insulated and uses little gas for heating
- the new boiler will be run at a high flow temperature with the old controls
In those cases, the better reasons to replace are reliability, safety, parts availability and warranty, not the fuel saving. Our guide on how long a boiler lasts covers the signs of a boiler near the end of its life, and our repair or replace guide helps you weigh it up.
Mistakes that cut into the saving
- Leaving the flow temperature at the maximum setting because that is how the old boiler was run.
- Keeping an old room thermostat in a cold hallway that keeps calling for heat.
- Skipping the system clean before the new boiler goes in.
- Choosing a boiler much bigger than the home needs.
- Missing the annual service, which lets efficiency drift over time.
Other benefits of a new boiler A modern boiler comes with a manufacturer’s guarantee, uses parts that are easy to get, and is set up and commissioned to current standards. For many households, avoiding breakdowns in winter matters as much as the gas saved.
How we price it
Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. You can get your price online in a couple of minutes with our boiler quote tool. Our other rates are published on our prices page. New boiler packages include a magnetic system filter, the first year’s service and removal of the old boiler. As Ideal Max accredited and Vaillant myREWARDS installers, we can offer manufacturer guarantees of up to 12 years on selected Ideal boilers and up to 10 years on selected Vaillant boilers.
Frequently asked questions
Does a new boiler reduce energy bills?
It reduces the gas you use for heating and hot water if your old boiler is less efficient than the new one. The bigger the gap in efficiency, the bigger the saving. Replacing a working condensing boiler with another saves much less.
Is it worth replacing a 15 year old boiler?
If it is a non-condensing boiler, the gas saving alone can be significant. If it is a condensing boiler that is reliable and serviced, the case rests more on reliability, parts and warranty than on fuel.
How much more efficient are new boilers?
New gas boilers in England must have an ErP efficiency of at least 92%. Older non-condensing boilers are often well below 80%, so the gap can be large.
Will a new boiler improve my EPC rating?
It can. The Energy Saving Trust lists upgrading an old boiler and adding full heating controls among the improvements that help an EPC rating, particularly when replacing a low-rated boiler.
Do I need new controls with a new boiler?
In England, every new gas boiler must have time and temperature controls, and a new combi needs at least one extra energy saving measure. Good controls are also where much of the real-world saving comes from.
New boilers in Hertfordshire, Bedfordshire and Cambridgeshire
We survey every home before quoting, check your current boiler and system, and give you an honest view of what a replacement will change. See our boiler installation page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374