To avoid condensation in a bathroom, remove the moist air at the source with an extractor fan that runs during every bath or shower and for a while afterwards, keep the room warm so walls and windows are not cold, and keep the door shut while you wash so steam does not spread. If you still see water running down walls and mould returning after that, the fan is probably too weak or blocked, or the room has a cold spot that needs fixing.

  • Condensation happens when warm, moist air meets a cold surface such as a window, tile or outside wall.
  • A working extractor fan is the most important fix. The Building Regulations guideline is 15 litres per second for a bathroom.
  • In a bathroom with no opening window, the fan should keep running for at least 15 minutes after you leave.
  • A warm room and a heated towel rail reduce cold surfaces where water forms.
  • Persistent damp that does not dry out may be a leak, not condensation.
White marble shower room fitted by Vantage
A marble shower room we designed and fitted.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

Why bathrooms get so much condensation

Government guidance on damp and mould explains that moisture produced inside the home cools and condenses onto colder parts of the building, such as windows, corners and outside walls. Showering and bathing release a lot of water vapour into a small room in a short time. When that warm, humid air touches cold glass, tiles or a ceiling under a cold loft, it turns back into water.

Left alone, that water soaks into grout, sealant, paint and plaster, and mould follows. The same guidance points out that damp and mould are a particular risk for people with asthma or other breathing conditions, children, older people and anyone with a weakened immune system.

Quick things you can do today

  1. Run the extractor fan every time you bath or shower, and leave it running afterwards.
  2. Keep the bathroom door shut while washing and until the steam has cleared, so moisture does not spread to colder rooms.
  3. Open the window after a shower if you have one, or leave it on the vent position. Government guidance recommends keeping trickle vents clear.
  4. Wipe down the shower screen, tiles and window with a squeegee or cloth after use.
  5. Keep the room warm. A cold bathroom has cold surfaces, and cold surfaces collect condensation.
  6. Do not dry washing in the bathroom without the fan running, and dry it outside when you can.
  7. Hang towels to dry on a heated towel rail rather than leaving them in a damp pile.
  8. Leave the shower curtain or door open after use so the tray dries out.

Make sure your extractor fan is doing its job

Most bathroom condensation problems come down to the fan. A fan that is weak, blocked, badly ducted or switched off early cannot remove the moisture fast enough.

What the Building Regulations expect

Approved Document F, the ventilation guidance under the Building Regulations, sets a minimum intermittent extract rate of 15 litres per second for a bathroom. In a room without an openable window, the fan should have controls that keep it running for at least 15 minutes after the room is vacated. When a bathroom is refurbished, any existing fan should be kept or replaced, so a bathroom renovation is the ideal moment to put in a fan that meets the guideline.

How to tell if your fan is working

  • The tissue test. Hold a single sheet of toilet paper near the grille with the fan running. It should be pulled firmly against the grille. If it barely moves, the fan is not moving much air.
  • Listen. A fan that is much louder than it used to be, or rattles, may have a failing motor.
  • Look at the grille. A grille thick with dust restricts airflow. Clean it with the power off.
  • Check the run-on. If the fan stops the moment the light goes off, it may not have an overrun timer.

Common fan problems

ProblemWhat you noticeWhat fixes it
Fan too small for the roomSteam lingers long after a showerA more powerful fan meeting the 15 l/s guideline
Blocked or crushed ductFan runs but hardly pullsClearing or rerouting the ducting to the outside
Duct not reaching outsideMoisture dumped into the loftDucting taken properly to an outside terminal
No overrun timerFan stops as soon as the light goes offA fan with a timer or humidity sensor
Fan wired to the light onlyNobody uses it in the daytimeA humidity-controlled fan that starts on its own

Replacing a fan like for like on existing cabling is a small electrical job. Approved Document F notes that replacing an extractor fan using existing cabling does not need to be notified to building control, but a new circuit does, and any electrical work near a bath or shower must be done by a competent person. Our electrical repairs and fault finding service can check and replace a fan that is not doing its job.

Warm up the cold surfaces

Condensation forms where surfaces are coldest, so warming them up reduces it.

  • Heating. A radiator or heated towel rail that actually warms the room makes a real difference. If your bathroom radiator stays cold at the bottom, see our guide to radiators not heating up.
  • Insulation. A ceiling below an uninsulated loft, or a solid outside wall, will always be a cold spot. Topping up loft insulation over the bathroom helps.
  • Windows. Old single glazing runs with water. Double glazing with trickle vents is warmer and lets moist air out.

Condensation, leak or damp?

Not every wet patch in a bathroom is condensation. It is worth ruling out the alternatives before you spend money on fans.

SignLikely causeWhat to do
Water on windows and tiles after showers, drying laterCondensationBetter extraction and heating
Black mould in corners, ceiling edges and on sealantCondensation over timeClean it, then fix the ventilation
A patch that stays damp even when nobody has showeredA leak from pipework, a waste or a trayGet the leak found and repaired
Damp on the ceiling below the bathroomA leak from the bath, shower or toiletHave it investigated before the ceiling is damaged
A tide mark low on a ground floor wallPossible rising or penetrating dampNeeds a proper damp survey

If you suspect a leak, our leak detection service can find it without unnecessary damage.

Cleaning mould safely Wear gloves, open a window and keep the fan running while you clean mould. Do not mix cleaning products, especially bleach with other cleaners. Switch off the power before cleaning the fan itself. Mould that keeps returning is a sign the cause has not been fixed, so treat the ventilation or leak, not just the stain.

When a renovation is the better fix

In some bathrooms, the layout, materials and ventilation all work against you: no window, an old fan in the wrong place, cold tiled walls and failing grout. A renovation lets you put a correctly sized fan in the right position with a proper duct to the outside, add a heated towel rail, use moisture-resistant boards and seal the shower properly. Our bathroom renovation team plans ventilation as part of every design, and our guide to common bathroom renovation mistakes covers other things to get right.

How we price it

Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. Smaller repairs and electrical work are charged at the rates on our prices page. Every bathroom we fit comes with a 12 month guarantee.

Frequently asked questions

How long should a bathroom extractor fan run after a shower?

In a bathroom with no opening window, Approved Document F says the fan should keep running for at least 15 minutes after you leave. Running it for a while afterwards helps in any bathroom.

Is condensation in a bathroom normal?

Some misting during and just after a shower is normal. Water running down the walls, puddles on sills and mould returning are signs that ventilation or heating is not good enough.

Does opening a window stop bathroom condensation?

It helps, especially after a shower, but on its own it is slow and can make the room cold. A working extractor fan with the door closed is more effective.

Should the bathroom door be open or closed after a shower?

Closed, with the fan running, until the steam has cleared. Opening the door lets moist air spread into colder rooms where it condenses instead.

Does a heated towel rail help with condensation?

Yes. It warms the room, which keeps surfaces warmer, and it dries towels that would otherwise add moisture to the air.

Bathroom help in Hertfordshire, Bedfordshire and Cambridgeshire

Whether you need a better fan, a leak found or a full refit with proper ventilation, we can help. See our bathroom renovation page or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.