To choose the right unvented cylinder, start with your incoming mains water, because an unvented cylinder can only deliver the pressure and flow your supply gives it. Then size it to how many bathrooms you have and how you use hot water, pick the type that suits your heat source (a boiler, an immersion heater, solar or a heat pump), and make sure it is fitted by someone with a G3 unvented qualification.

In short

  • An unvented cylinder stores hot water at mains pressure, so a weak mains supply means a disappointing cylinder. Test your flow before anything else.
  • Size it on bathrooms, baths and how many people shower at the same time, not just on the number of bedrooms.
  • Indirect cylinders heat from a boiler, direct cylinders from immersion heaters, and heat pump cylinders have a much larger coil.
  • Choose between an internal air bubble and an external expansion vessel, and think about where the discharge pipe will run.
  • Installation is controlled work under Part G3 of the Building Regulations, and the cylinder needs a yearly service.
Unvented hot water cylinder installed by Vantage
An unvented hot water cylinder we installed.

What an unvented cylinder is and why people choose one

An unvented cylinder is a sealed hot water tank fed straight from the cold mains. Because there is no cold water tank in the loft feeding it, the hot water comes out of your taps and shower at close to mains pressure. That means strong showers without a pump, several taps running at once, and the loft tanks can come out.

It is the usual choice when a home has two or more bathrooms, when a combi boiler cannot keep up, or when you are fitting a system boiler or a heat pump. Our unvented cylinder installation service covers the survey, the fitting and the yearly service.

Being sealed and under pressure is also why the rules are strict. Water heated in a closed vessel has nowhere to go as it expands, so the cylinder relies on controls and safety devices to stop the pressure and temperature rising too far.

Step 1: check your mains water supply

This is the step that most buying guides skip, and it matters more than the brand. An unvented cylinder does not boost your water. If only a trickle comes into the house, a trickle comes out of the shower.

There are two things to know:

  • Flow rate, measured in litres per minute. This is how much water your supply can deliver.
  • Dynamic pressure, measured in bar while water is flowing. Static pressure, measured with every tap closed, can look healthy and still collapse the moment you open a tap.

You can check the flow yourself in a couple of minutes:

  1. Make sure nothing else in the house is using water.
  2. Take a bucket or container of a known size.
  3. Open the kitchen cold tap fully (it is normally fed straight from the mains).
  4. Time how long it takes to fill.
  5. Divide the volume in litres by the seconds, then multiply by 60 to get litres per minute.

Each cylinder manufacturer publishes a minimum pressure and flow for its products in the installation instructions. A surveyor will measure both with a gauge and compare them with the model you have in mind. If your flow is poor, the cause may be an old lead or narrow supply pipe, a shared supply, or a partly closed stopcock. Our guide to low water pressure in the whole house explains what a plumber checks. Sometimes upgrading the supply pipe is the right first job.

Step 2: size it to how you use hot water

A cylinder that is too small runs out mid-bath. One that is too big costs more to buy, takes longer to heat and loses more heat standing still. Think about:

  • The number of bathrooms and en suites, and whether two showers could run at once.
  • Baths. A bath takes far more hot water than a shower, and a large bath can empty a small cylinder on its own.
  • How many people use hot water in the morning rush.
  • Recovery time. How quickly the cylinder reheats depends on the coil and the heat source. A boiler with a good coil reheats faster than an immersion heater.

As a rough starting point only:

Your homeTypical starting pointWhat pushes it up
One bathroom, mostly showersA smaller cylinder, at the lower end of the rangeA large bath, or a busy morning routine
Two bathrooms, or a bathroom and an en suiteA mid-sized cylinderTwo showers running at once
Three or more bathrooms, or a large familyA large cylinderLarge baths, body jets, slow reheat
Heat pump systemUsually larger than you would pick for a boilerLower stored temperature means less usable hot water per litre

Your installer should work it out from your actual outlets, not from a rule of thumb. If a quote gives a cylinder size without asking how many baths and showers you have, ask how they chose it.

Step 3: pick the right type for your heat source

TypeHow it heatsBest forThings to know
IndirectA coil carrying hot water from a system or regular boiler, with an immersion as back-upMost homes with a gas or oil boilerNot used with a combi boiler, which heats water on demand
DirectOne or two electric immersion heatersHomes without a boiler, often on off-peak electricityHeating costs depend on your tariff; reheat is slower
SolarA second, lower coil for solar thermal panelsHomes with or planning solar thermalNeeds the solar controls and pipework designed with it
Heat pumpA much larger coil to suit the lower flow temperature of a heat pumpAir source or ground source heat pumpsMust match the heat pump; a standard indirect cylinder is not a substitute
Slimline or horizontalSame principles, different shapeTight cupboards or lofts with limited heightOften a smaller volume for the same footprint

Some cylinders come pre-plumbed, with the valves and wiring already fitted, which can make for a neater installation in a cupboard. If you are also changing your boiler, plan the two together: our boiler installation team will match the boiler to the cylinder coil so the hot water reheats as it should.

Step 4: decide on expansion and the discharge route

When water is heated it expands. In a sealed cylinder that extra volume has to go somewhere, and there are two ways of dealing with it:

  • Internal air bubble. A pocket of air at the top of the cylinder takes up the expansion. There is no separate vessel to find a home for, but the air gap needs recharging as part of the service.
  • External expansion vessel. A separate vessel on the cold inlet with a pressurised air charge. It needs wall space nearby, and its charge should be checked each year.

Every unvented cylinder also needs a discharge pipe. If a safety valve ever opens, hot water has to run through a tundish (an open funnel you can see) and then a pipe to a safe, visible point outside. Approved Document G sets out how this pipe must be run, including the tundish being within 600mm of the valve outlet and a vertical drop of at least 300mm below it before any bend. In practice, the route for this pipe often decides where the cylinder can go, so bring it up early.

Step 5: compare build quality and heat loss

  • Material. Most modern unvented cylinders have a stainless steel inner tank. Stainless resists corrosion well, which matters in hard water areas like most of Hertfordshire.
  • Insulation and standing losses. Every cylinder loses heat when it is not being used. The energy label and the product data give a heat loss figure. Lower is better, and thicker factory insulation helps.
  • Guarantee terms. Manufacturers often offer long guarantees on the inner tank, but these usually depend on the cylinder being installed by a qualified person, registered, and serviced every year. Read the conditions.
  • Hard water. Limescale builds up on the coil and immersion heater over time and slows the reheat. If your water is very hard, ask whether a water softener makes sense for your home.

The rules: G3 and building control

Unvented hot water storage is covered by Part G3 of the Building Regulations in England. The key points for a homeowner are:

  • The system must have at least two independent safety devices on top of the normal thermostat, typically a non-self-resetting energy cut-out and a temperature and pressure relief valve, so the stored water can never go above 100C.
  • It must be installed by a competent person. In England and Wales that means someone holding a G3 unvented qualification. Manufacturers say the same in their own guidance.
  • The work must be notified to building control. An installer registered with a competent person scheme can self-certify it, so you do not need to apply in advance.
  • Small water heaters of 15 litres or less with the right safety devices are treated differently, which is why an under-sink water heater has lighter rules than a full cylinder.

Do not adjust the safety devices

  • Never cap, block or plug the tundish or discharge pipe, even if it drips. A drip is a warning that something needs attention.
  • Never adjust or remove the temperature and pressure relief valve, the expansion relief valve or the energy cut-out.
  • If you see hot water or steam coming from the tundish, switch off the boiler or immersion heater and call an engineer.

Mistakes to avoid when choosing

  • Buying before testing the mains. The most common cause of an unvented cylinder that disappoints.
  • Sizing on bedrooms. A four-bedroom house with one shower and a family that never takes baths may need less than a three-bedroom house with two baths.
  • Forgetting the discharge pipe. A cylinder in the middle of the house can be hard to pipe to outside.
  • Fitting a standard cylinder to a heat pump. The coil will be too small and the hot water will struggle.

How we price it

Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. The survey covers your mains flow and pressure, where the cylinder and discharge pipe can go, and how it will connect to your boiler or heat pump. Servicing and repairs are charged at our published rates, and every rate is on our prices page, so you know what you will pay before we arrive.

Frequently asked questions

Can I have an unvented cylinder with a combi boiler?

No, not in the usual sense. A combi heats water on demand and has no cylinder coil to connect to. If you want an unvented cylinder, the combi is normally replaced with a system boiler, which heats the cylinder through its coil.

What happens if my water pressure is too low for an unvented cylinder?

The cylinder will work, but the showers and taps will only be as good as the supply. The fix is often a new, larger supply pipe from the boundary to the house. In some cases a different hot water system is the better answer, and the survey should tell you which.

Does an unvented cylinder need servicing every year?

Yes. Manufacturers recommend a yearly service, which checks the safety valves, the expansion vessel or air gap, the pressure reducing valve and the controls. Most tank guarantees depend on it being done.

Where can an unvented cylinder go?

Almost anywhere with a strong enough floor, a mains supply and a route for the discharge pipe to outside. Airing cupboards, utility rooms, garages and lofts are all common. The discharge route and the weight of a full cylinder are usually what decide it.

Help choosing a cylinder in Hertfordshire, Bedfordshire and Cambridgeshire

If you are weighing up an unvented cylinder, we will measure your mains supply, size the cylinder to your home and give you a fixed price. See our unvented cylinder service or call 01462 506374. The phone is answered 24 hours a day, 7 days a week.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.