How to Increase Water Pressure in Your Shower
Hertfordshire, Bedfordshire & Cambridgeshire
To increase shower pressure, start with the free fixes: descale the shower head, straighten or replace the hose, and make sure the stop tap and any isolation valve on the shower supply are fully open. If that does not help, the right fix depends on your system. A gravity-fed shower (tank in the loft) can usually be boosted with a shower pump, while a mains-fed shower from a combi or unvented cylinder is limited by the water coming into your home, and pumping it needs care and sometimes the water company’s consent.
In short
- Limescale in the shower head is the most common cause in Hertfordshire’s hard water. Descale it first.
- Work out your system: electric, gravity-fed, combi or unvented cylinder. The fix is different for each.
- Gravity-fed showers are the easiest to boost, usually with a shower pump.
- You cannot simply fit a pump to a combi or mains supply. Pumps drawing more than 12 litres a minute need water company consent.
- If every tap in the house is weak, the problem is the supply, not the shower.

Pressure or flow?
People say “pressure”, but what you notice in a shower is usually flow, the amount of water coming out each minute. Pressure pushes the water, and anything narrow, blocked or partly closed along the way cuts the flow. That is why a shower can be weak even when the mains pressure is fine, and why the first checks are all about blockages and valves. If you would rather hand it over, our shower installation engineers can test your supply and fix or replace the shower.
Quick checks you can do today
- Descale the shower head. Unscrew it, soak it in white vinegar or a limescale remover for an hour or so, then rub the nozzles clear. Many heads have flexible rubber nozzles you can simply rub with a thumb.
- Check the hose. A kinked or collapsed hose cuts flow. Take it off and run the water through the valve without it. If the flow is much better, replace the hose.
- Look for a flow restrictor. Many shower heads and some hoses contain a small flow regulator to save water. If it is removable, taking it out can make a noticeable difference. Some are designed to stay in.
- Open the valves fully. Check the main stop tap, often under the kitchen sink, is fully open. Then look for small isolation valves on the pipes to the shower, often with a screwdriver slot. The slot should line up with the pipe.
- Test the kitchen cold tap. Water industry guidance is that the first tap in the home, usually the kitchen cold, should fill a 4.5 litre bucket in about 30 seconds with nothing else running. If it cannot, the problem is your supply, not the shower.
- Check what else is running. A washing machine, dishwasher, garden hose or someone else in another bathroom all share the same supply.
If all your taps are weak, read our guide to low water pressure in the whole house, which covers supply pipes, stop taps and leaks.
Which shower system do you have?
| System | How to recognise it | Typical cause of poor flow | Usual fixes |
|---|---|---|---|
| Electric shower | A box on the wall with its own switch, heats cold mains water | Scale in the heater or head, low mains flow in winter, an old low-power unit | Descale, check the supply, replace with a higher-rated unit |
| Gravity-fed mixer | Hot water cylinder in an airing cupboard and a cold water tank in the loft | Little height between the tank and the shower head | Shower pump, or raising the tank |
| Power shower | Mixer and pump in one unit, fed from tanks | Failing pump, blocked filters | Service or replace the unit |
| Mixer on a combi | No tanks, no cylinder, hot water from the boiler | Mains flow, a combi too small for the flow, scaled heat exchanger | Better head, boiler service, accumulator, supply upgrade |
| Mixer on an unvented cylinder | A cylinder under mains pressure, no loft tanks | Blocked strainer or pressure reducing valve set low | Engineer to check the cylinder controls |
Fixes for gravity-fed showers
Gravity-fed showers rely on the height of the cold water tank above the shower head. One metre of height gives only a tenth of a bar, so a tank in a low loft above a first floor shower gives very little push. This is the system where a pump helps most.
- A shower pump takes water from the tank and cylinder and boosts it to the shower. It must be the right type: a positive head pump if water flows from the shower by gravity with the pump off, or a negative head pump if it does not. It needs its own supply from the cylinder in many cases, and the cylinder must be suitable for the extra flow.
- Raising the cold water tank in the loft increases the head a little, if there is room.
- Replacing the whole system with an unvented cylinder, if your mains supply is good enough, gives mains pressure hot and cold water throughout the house. Our unvented cylinder page explains how that works.
Fixes for combi and mains-fed showers
A combi or unvented cylinder already delivers water at mains pressure, so the shower can only be as good as the supply coming into your home. The water company’s guaranteed minimum is 7 metres of static head (0.7 bar) at the boundary of your property, and most areas get more.
- Get the boiler serviced. A scaled plate heat exchanger in a combi can cut hot water flow and make it run hot and cold. Our guide to a shower running hot and cold explains why.
- Check the valve filters. Many thermostatic bar mixers have small filters in the inlets that clog with scale and debris.
- Choose the right shower head. A head designed for mains pressure, or a larger rainfall head on a good supply, feels better. On a weak supply, a smaller head with narrower nozzles often feels stronger.
- A cold water accumulator stores mains water under pressure and releases it at peak times, which helps homes where flow drops when several outlets are used.
- Upgrade the supply pipe. Older homes can have a narrow or corroded lead or steel supply pipe. Replacing it can transform flow, but it is a bigger job.
Rules and safety
- Do not fit a pump to a combi boiler or directly to the mains supply. Under the Water Supply (Water Fittings) Regulations, a pump or booster drawing more than 12 litres a minute from a supply pipe needs the water supplier’s consent first.
- Most pumps are designed for gravity-fed systems only. Check the manufacturer’s instructions for your system type.
- Changing or adding an electric shower usually means electrical work in a bathroom, which is notifiable under Part P of the Building Regulations. Use a registered electrician.
- Do not open the boiler to descale it. Work inside a gas boiler is for a Gas Safe registered engineer only.
Fixes for electric showers
An electric shower heats cold water as it passes through, so its flow is limited by its power rating. In winter the incoming water is colder, so the shower slows the flow to keep the temperature up. That is normal. If it is weaker than it used to be, scale in the head or heater is the usual cause. A higher-rated unit gives more flow, but the cable and circuit must be big enough, which an electrician needs to check.
Replace or upgrade the shower?
If the valve is old, scaled or keeps losing flow, replacing the shower can be simpler than chasing each fault. Our shower installation team can match the right shower to your water system, so it works properly from day one rather than fighting the supply.
What it costs with Vantage
For repairs, in normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. If the combi needs attention, gas work starts with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
New showers, pumps and bathroom installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. Our labour carries a 12 month guarantee, and full bathroom installations carry a 12 month guarantee.
Frequently asked questions
Can I put a shower pump on a combi boiler?
No. A combi is fed directly from the mains, and pumping from the mains is restricted under the water regulations. Most shower pumps are only designed for gravity-fed systems. If a combi shower is weak, look at the supply, the shower head and the boiler instead.
Why is my shower pressure suddenly low?
A sudden drop usually points to a blockage (a scaled head or a clogged valve filter), a partly closed valve, work on the water main in your street, or a leak. Check whether the other taps are affected, then check with your water company for work nearby.
Does a water softener improve shower pressure?
Not directly, but it stops limescale building up in shower heads, valves and combi heat exchangers, which is what slowly chokes flow in hard water areas like Hertfordshire. See our water softener installation page.
Will a new shower head increase pressure?
It can make the shower feel stronger. A head with fewer, narrower nozzles speeds the water up on a weak supply. A new head will not add flow that is not there.
Why is my shower weak upstairs but fine downstairs?
On a gravity-fed system, the upstairs shower has less height below the loft tank, so less pressure. On a mains system, a long or narrow pipe run to the top of the house can cut the flow. An engineer can measure both.
Better showers across Hertfordshire, Bedfordshire and Cambridgeshire
If the quick fixes have not worked, our plumbers can test your supply and recommend the fix that suits your system. See our shower installation page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Bathroom fitters near you
Planning a new bathroom? Our own team designs and fits it
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374