To remove air from water pipes, open your taps one at a time, starting with the lowest tap in the house and working upwards, and let each run until the flow is smooth, which clears most air after the water has been turned off. If one tap, usually a hot tap fed from a tank in the loft, will not flow at all, you have an airlock, and the usual fix is to push mains pressure water back through it with a short hose from a cold mains tap.
In short
- Spluttering taps and cloudy water that clears from the bottom of a glass are signs of air, and the air itself is harmless.
- Air usually gets in after the water supply has been off, after draining down, or when a cold water tank runs low.
- Running the taps from the lowest to the highest clears most air on mains pressure systems.
- Airlocks are most common in low pressure, tank-fed hot water systems, where there is not enough pressure to push a bubble past a high point.
- If air keeps coming back, something is letting it in, such as a faulty float valve in the loft tank or a leaking joint, and that needs fixing.
Signs of air in your water pipes
- Spluttering or spitting taps, often with bursts of air and water.
- Cloudy or white water that clears from the bottom of the glass upwards. The Drinking Water Inspectorate says this is caused by tiny air bubbles and is not harmful to health.
- Weak or no flow from one tap while others work normally. This is the classic airlock, and it is usually a hot tap.
- Gurgling or knocking as air moves through the pipes.
- A shower or tap that runs, stops and starts again.
Loud banging when a tap is turned off quickly is a different problem, usually water hammer rather than air. Our guide on banging pipes and water hammer covers that.
Why air gets into water pipes
| Cause | What happens | What you might notice |
|---|---|---|
| Water supply turned off | When the mains or your stop tap is turned back on, air trapped in the pipes comes out through the taps | Spluttering and cloudy water after work in the street or at home |
| System drained down | Pipes refill with air pockets at high points and bends | Taps spit, one hot tap does not run |
| Cold water tank running low | The float valve in the loft tank sticks or the supply is restricted, so air is drawn into the pipe feeding the hot cylinder | Hot taps splutter or stop after heavy use, such as a bath |
| Leaking or loose joint | Air is drawn in where the pipe is not sealed | Air returns again and again |
| Pipe layout | Air collects where a pipe rises and falls, such as over a door frame | One tap or shower affected repeatedly |
| New plumbing work | Air left in new pipes that have not been flushed | Spluttering for a short time after the work |
Most of these are simple to put right, and if you would rather a plumber dealt with it, airlocks and the faults that cause them come under our general plumbing repairs service.
Why tank-fed hot water gets airlocks
In homes with a combi boiler or an unvented cylinder, both hot and cold are at mains pressure, which is usually strong enough to push air out through the taps. Airlocks there are rare and short-lived.
In homes with a hot water cylinder fed from a cold water tank in the loft, the hot water relies on gravity. The pressure comes only from the height of the tank above the tap, roughly 0.1 bar for every metre, so an upstairs tap may have only a small fraction of mains pressure. A bubble of air trapped at a high point in the pipe can be enough to stop the water altogether. That is why airlocks nearly always affect hot taps and gravity-fed showers.
How to clear air from your pipes, step by step
Try these in order, stopping when the flow returns to normal.
1. Run the taps from the bottom up
- Make sure the stop tap is fully open.
- Start with the lowest tap in the house, usually the kitchen cold tap, and open it fully.
- Let it run until the flow is steady and the water is clear.
- Move to the next tap up, and work your way through the house to the highest.
- Do the same with the hot taps.
- Flush each toilet once.
This clears most air after a supply interruption. Cloudy water that clears in a glass is normal and will settle within a day. If it does not, contact your water supplier.
2. Check the cold water tank in the loft
If you have a tank-fed system and the hot taps have stopped, look at the cold water storage tank first, if you can get to it safely. If the water level is well below normal, the float valve may be stuck or the supply to it restricted. Clearing an airlock will not last while the tank is running low, so that needs fixing first.
3. Clear an airlock with a hosepipe
This is the method most plumbers use for a stubborn airlock on a tank-fed hot tap. It uses the higher pressure of the mains cold supply to push the air bubble back up the pipe and out through the tank.
- Take a short length of clean hosepipe and connect one end to a mains-fed cold tap, usually the kitchen cold tap, and the other end to the airlocked tap. Use hose clips or tap connectors so it stays on.
- Open the airlocked tap fully.
- Open the mains cold tap for a few seconds at a time. You may hear air and water moving back through the pipes.
- Close the mains tap, then the airlocked tap, and remove the hose.
- Run the airlocked tap to see if it flows normally. Repeat once or twice if needed.
Using the hosepipe method safely
- Only connect the hose for as long as it takes. Connecting mains water to stored hot water, even briefly, creates a risk of water flowing back into the mains, so never leave it connected.
- Use a clean hose, not one that has been lying in the garden, and run the kitchen cold tap for a minute afterwards.
- Do not use this method on an unvented cylinder, a combi boiler or any system you are not sure about. Those are at mains pressure, so an airlock is unlikely and the cause is probably something else.
- If the tap still will not run after two or three attempts, stop and call a plumber.
4. Drain down and refill
If the airlock will not shift, the system can be drained and refilled. Turn off the stop tap, open the affected taps and the lowest tap in the house, and let them drain. Then close the taps, starting with the lowest, and open the stop tap slowly so the pipes refill gradually. On a tank-fed hot system, draining down properly involves isolating the cylinder and tank, so if you are not confident, leave this to a plumber.
Air in the heating system is a different problem
Air in the central heating circuit shows up as radiators that are cold at the top, gurgling in the pipes or a boiler that makes kettling noises. It does not come out through your taps, and it is cleared by bleeding the radiators. Our guide on how to bleed a radiator explains how, and on a sealed system you will need to check the boiler pressure afterwards.
When the air keeps coming back
If you clear the air and it returns within days, something is letting air in or the system is running short of water. Common causes are:
- a faulty float valve or a restricted supply to the cold water tank
- a hot water cylinder feed that is too small for the demand
- a leaking or poorly made joint on the pipework
- a pipe run with a high loop where air collects
- a pump, such as a shower pump, that is struggling on a poor supply
A plumber will check the tank and float valve, the pipe sizes and the layout, and correct anything that is trapping or drawing in air. If pressure is poor everywhere rather than at one tap, see our guide to low water pressure in the whole house.
If there is no hot water at all, rather than a spluttering tap, the problem may be the boiler or cylinder rather than an airlock. Our guide on no hot water but heating works goes through those causes.
What a plumber will do
A plumber will find where the air is getting in, clear any airlocks, and put right the cause. That might mean replacing a float valve in the loft tank, remaking a joint, rerouting a section of pipe to remove a high point, or advising on an upgrade. Where tank-fed pressure is always poor, some homes benefit from an unvented cylinder, which runs hot water at mains pressure. All of this comes under our general plumbing repairs service.
What it costs with Vantage
In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
Frequently asked questions
Will an airlock clear itself?
Sometimes. Air after a supply interruption usually clears once the taps have been run. A true airlock in a tank-fed hot pipe often does not clear on its own, because there is not enough pressure to push the air past the high point, so it needs the hosepipe method or a plumber.
Is air in water pipes dangerous?
No. The air itself is harmless, and cloudy water caused by air is safe to drink. The problems it causes are practical: no flow from a tap, noise and spluttering. If the water is discoloured rather than cloudy, contact your water supplier.
Why are my taps spitting after the water was turned off?
When the water supply is turned off, the pipes partly empty and fill with air. When it is turned back on, that air comes out through your taps. Run each tap, lowest first, until the flow is smooth.
Why does only my hot tap have an airlock?
In a tank-fed system the hot water runs at a much lower pressure than the cold, which comes from the mains. That low pressure is not enough to push a trapped bubble through the pipe, so hot taps and gravity showers are the ones that airlock.
Can air in the pipes damage my boiler?
Air in the taps and water supply pipes does not affect a combi boiler’s heating side. Air in the heating system itself can cause noise and cold radiators, and should be bled out. If a combi boiler’s hot water flow is erratic, that is worth getting checked.
When to call a plumber
If a tap still will not run after trying the steps above, the air keeps coming back, or you are not sure what type of system you have, it is time to call a plumber. Our own engineers cover Hertfordshire, Bedfordshire and Cambridgeshire from our Stevenage base. Book through our general plumbing repairs page or call 01462 506374, answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Leak detection near you
Suspect a hidden leak? We find it without digging up your floor
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374