Skip to main content

Vantage Plumbing and Heating

Plug Socket Not Working: Causes and What to Check

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

A plug socket that has stopped working is usually caused by something simple: a blown fuse in the plug, a tripped circuit breaker or RCD at the consumer unit, or a faulty appliance rather than a faulty socket. If those checks do not bring it back, or the socket is scorched, buzzing, warm or smells of burning, stop using it and have an electrician find the fault, because a loose or damaged connection can cause a fire.

  • First prove it is the socket: plug in a lamp or phone charger you know works.
  • Check the fuse in the plug, then look at the consumer unit for a tripped switch or RCD.
  • If several sockets have gone off at once, the fault is on the circuit, not the socket.
  • A switch that trips again straight away is telling you there is a fault. Do not keep resetting it.
  • Scorch marks, heat, crackling or a burning smell mean switch off and call an electrician.

Check these first

These checks are safe for anyone to do and they solve a large share of “dead socket” problems.

  1. Test with something you know works. Plug a lamp or phone charger into the socket. If it works, the socket is fine and the problem is the original appliance or its lead.
  2. Check the socket switch. It sounds obvious, but a switch that is part-way on, or a double socket where you are using the side that is switched off, catches people out.
  3. Try the appliance in another socket. If it does not work anywhere, the appliance, its lead or its plug fuse is the problem.
  4. Check the plug fuse. If the appliance has a standard UK plug, replace the fuse with a new one of the rating shown on the appliance or its instructions (commonly 3A for low-power items and 13A for kettles, heaters and similar). Never fit a higher rating than specified.
  5. Look at the consumer unit. Find your fuse box and look for any switch that is down or in the middle position. Note which one it is.
  6. Reset once. Unplug everything on that circuit, then push the tripped switch back up. If it stays on, plug things back in one at a time. If it trips when a particular appliance goes back in, that appliance is the likely culprit.
  7. Check any fused spur. Sockets in kitchens, outbuildings and some extensions can be fed from a fused connection unit (a plate with a small fuse carrier and often a switch). Check it is switched on and, if it has a fuse, whether it has blown.

Stop and call an electrician if you see any of these

  • Brown or black scorch marks on the socket or plug
  • The socket or plug feels warm or hot to touch
  • Crackling, buzzing or popping sounds
  • A smell of hot plastic or burning
  • A switch at the consumer unit that trips again as soon as you reset it, even with everything unplugged

Switch the circuit off at the consumer unit and do not use the socket until it has been checked. Never take the front off a socket while the power is on, and never try to bypass or tape down a trip switch.

What the consumer unit is telling you

Your consumer unit (fuse box) protects every circuit in the house. Understanding what tripped helps you and the electrician.

What you seeWhat it usually meansWhat to do
One circuit breaker (MCB) is downThat circuit was overloaded or has a fault such as a short circuitUnplug everything on the circuit and reset it once. If it trips again with nothing plugged in, call an electrician
An RCD or RCBO is downCurrent has leaked to earth, often from a faulty appliance, damp or a damaged cableUnplug appliances on the affected circuits, reset, and plug back in one at a time to find the culprit
Nothing is tripped but the socket is deadA loose connection, a failed socket, a blown fuse in a spur, or a break in the circuit wiringNeeds an electrician to test the circuit
Old rewireable fuses, no switchesAn older installation where a fuse wire may have meltedDo not rewire fuses yourself unless you know how. Have the installation checked

If your consumer unit has an RCD, it will have a test button marked T or Test. Pressing it should switch off the circuits it protects. Electrical Safety First advises that if you do not have an RCD, or it does not work, you should use plug-in RCDs for your sockets until the installation is upgraded.

Common causes of a socket not working

CauseWhat you might noticeCan you fix it yourself?What the electrician does
Faulty appliance or leadThe appliance does not work in any socketYes, stop using it and repair or replace itCan test the appliance if you are unsure
Blown plug fuseAppliance dead, socket fine with other itemsYes, replace with the correct ratingNothing needed
Tripped breaker or RCDSeveral sockets off, a switch down at the consumer unitYes, reset once after unpluggingFinds the cause if it keeps tripping
Overloaded circuitTrips when heaters, kettles or tumble dryers run togetherPartly, by spreading heavy loadsChecks the circuit design and may add a new circuit
Loose or burnt connectionSocket works on and off, feels warm, scorch marksNoIsolates, replaces the socket and remakes connections
Worn socket contactsPlugs feel loose and fall out easilyNoReplaces the socket
Break in a ring circuitSocket dead with nothing tripped, others on the circuit may still workNoTests the ring end to end and repairs the break
Water or dampTrips after rain, outside or in kitchens and utility roomsNoFinds the entry point, dries or replaces the fitting
Damaged cableTrips after drilling, nailing or building workNoTraces and repairs the cable

Why a socket can die with nothing tripped

Most UK homes have sockets on a ring final circuit, where the cable runs from the consumer unit around the sockets and back again. If a connection in one socket works loose, the sockets beyond it may keep working because they are still fed from the other side of the ring, so nothing trips. That hides the fault, and a loose connection under load gets hot. This is exactly the kind of fault that needs testing with the right instruments rather than guesswork, and our electrical repairs and fault finding engineers trace them every week.

Why a whole row of sockets goes off

If every socket in a room, a floor or the kitchen goes off at once, the circuit protecting them has tripped or has a fault. On newer installations an RCD may protect several circuits, so one faulty appliance can take out sockets in more than one room. Unplugging everything and plugging back in one by one is the quickest way to find the appliance responsible.

What an electrician will check

  1. Safe isolation. The circuit is switched off and proved dead with a tester before the socket is opened.
  2. The socket and its connections. Looking for loose terminals, scorching, damaged insulation and cables that have been over-stripped or pinched.
  3. Circuit tests. Continuity of the ring or radial circuit, insulation resistance to find damaged cable, and polarity.
  4. The protective device. Checking the breaker or RCD is the right type and rating and is operating correctly.
  5. The load. Whether the circuit is being asked to carry more than it was designed for, such as several heaters on one kitchen circuit.

If the fault is simply a worn or damaged socket, replacing it is quick. If the testing shows wider problems, such as old wiring or no RCD protection, the electrician will explain what they found and what it would take to put right. An EICR electrical safety check gives you a full report on the whole installation if you want to know where you stand.

Preventing socket problems

  • Do not daisy-chain extension leads or run high-power appliances such as heaters and tumble dryers from an extension.
  • Replace sockets that grip plugs loosely. Poor contact causes heat.
  • Keep liquids away from sockets and do not use sockets that have got wet until they have dried and been checked.
  • Test your RCD using the test button, as the label on your consumer unit advises.
  • Get older installations checked. If your consumer unit has rewireable fuses, no RCD, or the wiring is decades old, a condition report is worth having.

What it costs with Vantage

In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts, such as a replacement socket, are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. Our work carries a 12 month labour guarantee.

If you are choosing someone for the job, our guide on how to choose an electrician in Hertfordshire explains what to look for.

Frequently asked questions

Why are my sockets not working but nothing has tripped?

The most likely causes are a loose or failed connection in one socket, a blown fuse in a fused spur, or a break in the circuit wiring. Because a ring circuit is fed from both ends, a break can leave some sockets working and others dead without tripping anything. This needs testing by an electrician.

Is a dead plug socket dangerous?

A socket that is simply dead is not dangerous in itself, but the cause might be. A loose connection can get hot and damage the socket and cable. If there are scorch marks, heat, crackling or a burning smell, switch off the circuit and have it checked straight away.

Can I replace a plug socket myself?

Replacing a like-for-like socket front in a dry room is not notifiable work under Part P of the Building Regulations, but it must still be done safely and correctly. If you are not confident isolating the circuit, proving it dead and making sound connections, leave it to an electrician. Work in bathrooms and new circuits have extra rules.

Why does my RCD keep tripping?

An RCD trips when it detects current leaking to earth. Common causes are a faulty appliance, often a kettle, washing machine or outdoor item, damp getting into a socket or light, or a damaged cable. Unplug everything and reset it. If it holds, plug appliances back one at a time. If it trips with everything unplugged, the fault is in the wiring.

Can a plug socket just stop working?

Yes. Sockets have springs and contacts that wear, and connections behind them can work loose over years of plugs going in and out. A socket that suddenly stops, with nothing tripped and everything else in the room working, often has a loose or failed connection.

When to call an electrician

If the simple checks do not bring the socket back, the breaker keeps tripping, or you see any sign of heat or burning, our electrical repairs and fault finding team can test the circuit, find the fault and put it right. We cover Hertfordshire, Bedfordshire and Cambridgeshire from Stevenage, with 24/7 emergency cover. Call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.