A shower head that drips for a few minutes after you turn it off is usually just water draining out of the hose and head, and that is normal. A drip that carries on for hours, or never stops, means water is getting past the valve: on a mixer shower that is usually a worn or dirty cartridge or washer, and on an electric shower it is usually the solenoid or flow control valve.

In short

  • Dripping that stops within a few minutes is trapped water draining out. No fix needed.
  • A constant drip on a mixer shower points to a worn or scaled cartridge, a failed washer or debris in the valve.
  • A constant drip on an electric shower usually means the solenoid valve or flow control valve has failed.
  • On a bath shower mixer, the diverter can let water through to the head.
  • Limescale is a common cause in Hertfordshire, where most homes have hard water.
White marble shower room fitted by Vantage
A marble shower room we designed and fitted.

First, is it actually a fault?

When you turn a shower off, the water already in the hose, the riser and the head has to go somewhere. It drains out slowly through the nozzles. A large overhead drench head can hold a surprising amount and may drip for several minutes. That is not a leak.

Try this simple test:

  1. Turn the shower off and note the time.
  2. Come back after 15 to 20 minutes.
  3. If the drip has stopped, it was draining water. If it is still dripping at the same rate, water is getting past the valve and something needs fixing.

A constant drip is worth sorting out. It wastes water, it leaves limescale on the tray and glass, and if the hot side is passing, it wastes heated water too. Our bathroom repairs team fixes dripping showers of all types.

Work out what kind of shower you have

The cause depends on the type of shower, so start here.

Shower typeHow to recognise itUsual cause of a constant drip
Thermostatic bar mixerA horizontal bar on the wall with a temperature knob and a flow knobWorn or scaled flow cartridge, or debris in the valve
Concealed mixerOnly the controls show on the wall, with the valve buried behind the tilesWorn or scaled cartridge in the valve body
Older manual or two-handle mixerSeparate hot and cold handles, or a single lever with no temperature controlWorn washer or seal
Electric showerA box on the wall with a pull cord switch, fed by cold water onlySolenoid valve or flow control valve
Power showerA box on the wall with a built-in pump, fed from tanksFaulty valve inside the unit
Bath shower mixerBath taps with a shower hose and a diverter knobWorn diverter, or a passing tap

The common causes

Worn or scaled cartridge on a mixer shower

Most modern mixer showers use a cartridge to turn the flow on and off. Over time the seals inside wear, and in hard water areas limescale builds up on the moving parts. Either way, the cartridge no longer closes fully and a little water gets through. Triton’s own guidance for mixer showers that drip when off is to check for debris in the valve, and says a damaged cartridge will need replacing.

Debris in the valve

Grit, flakes of scale or bits of old pipework can lodge in a valve and stop it sealing. This is common after plumbing work, or after the water supply has been turned off and on again.

Worn washers on older valves

Older manual and two-handle shower valves use rubber washers that close against a seat. When the washer hardens or wears, it drips, just like a worn tap washer.

A failed solenoid or flow control valve on an electric shower

An electric shower uses an electrically operated valve to let cold water in. When it fails, water can seep through with the shower switched off. Triton says a continuous drip from an electric shower when switched off points to a mechanical fault inside the flow control valve or solenoid valve, and that these parts are not serviceable, so they are replaced rather than repaired.

A passing diverter on a bath shower mixer

On a bath mixer with a shower hose, the diverter switches the water between the bath spout and the shower. If its seal wears, water can reach the shower head when the taps are off or when you are running the bath.

Limescale

Most of Hertfordshire has hard water. Scale builds up on cartridges, washers and valve seats, stopping them closing properly, and it also blocks nozzles on the shower head. That can make the head hold water and drip for longer after use. If scale keeps coming back on every tap and shower in the house, a water softener deals with it at the source.

What you can safely check yourself

  1. Do the 20 minute test above to rule out normal draining.
  2. Clean the shower head. Soak it in a descaler or a mix of white vinegar and water, then rub the rubber nozzles to clear them. This helps if the head is holding water, although it will not stop a passing valve.
  3. Work the controls. Turn the flow control fully on and off a few times. Sometimes a small bit of debris clears from the cartridge.
  4. Find the isolation valves. Many mixer showers have small service valves on the hot and cold supplies, often behind a bath panel or access hatch. Turning these a quarter turn with a flat screwdriver stops the drip while you arrange a repair.
  5. On an electric shower, switch it off at the isolating switch. This is usually a pull cord or a wall switch outside the bathroom. Do not open the shower cover. It contains mains electrical parts.
  6. Check the bath diverter. If you have a bath mixer, see whether the drip changes when you move the diverter.

Stay safe Never remove the cover of an electric shower. It contains live mains parts even when the shower is off at the unit. Replacing a solenoid or flow valve on an electric shower is a job for a competent engineer. If water is getting into the electric shower casing, switch it off at the isolator and do not use it until it has been checked.

Can you replace a shower cartridge yourself?

On an exposed bar mixer with isolation valves, a competent DIYer can sometimes replace a flow cartridge, as long as they can identify the exact part and isolate the water. It gets harder quickly:

  • Cartridges are specific to the make and model, and many look similar.
  • Concealed valves sit behind tiles, and access is limited.
  • Without working isolation valves, the whole house supply has to be turned off.
  • Overtightening or damaging a seal can turn a drip into a leak behind the wall. If you ever see damp or staining around a concealed valve, our leak detection service can find the source without opening up more than necessary.

If the shower is old, parts are no longer made or you cannot identify it, an engineer will either find a compatible part or advise on replacing the valve.

What an engineer will do

  1. Confirm the drip is from the valve, not from trapped water or a problem elsewhere.
  2. Identify the shower and the exact part, from the model details or the valve itself.
  3. Isolate the supply at the service valves or, if there are none, at the stopcock.
  4. Clean, descale or replace the cartridge, washer or diverter, or on an electric shower, replace the solenoid or flow valve.
  5. Test the shower through its full range of temperature and flow, and check for leaks.

If a shower also struggles to hold a steady temperature, the same cartridge can be the cause. Our guide to a shower running hot and cold covers that problem.

Repair or replace?

A dripping shower is usually a repair. Replacement makes more sense when:

  • The shower is old and parts are no longer available.
  • An electric shower has several faults, or the casing is cracked or scorched.
  • The valve is concealed, and the repair would mean opening up tiling anyway.
  • You were planning to upgrade the shower.

If you decide to replace it, our shower installation service covers mixer, electric and pumped showers.

What it costs with Vantage

In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Frequently asked questions

Is it normal for a shower head to drip after use?

Yes, for a few minutes. Water left in the hose and head drains out through the nozzles. If the drip is still going 15 to 20 minutes later, the valve is letting water through.

Why is my electric shower dripping when it is switched off?

Most often the solenoid valve or flow control valve inside the unit has failed and is letting cold water seep through. These parts are replaced rather than repaired, and the shower cover should only be removed by a competent engineer.

Can a dripping shower increase my water bill?

If you are on a water meter, a constant drip adds up over weeks and months. If the hot side is passing, you also pay to heat water that goes straight down the drain.

How do I stop my shower dripping until it is repaired?

Close the isolation valves on the shower supply if there are any, usually with a quarter turn of a flat screwdriver. If there are none, you can turn off the stopcock, but that cuts off water to the whole house.

Can limescale cause a shower to drip?

Yes. Scale on a cartridge or valve seat stops it closing fully, and blocked nozzles make the head hold water for longer. In hard water areas, regular descaling of the head and a cartridge change when needed keep the shower working properly.

Shower repairs in Hertfordshire, Bedfordshire and Cambridgeshire

If your shower keeps dripping after you turn it off, our own engineers can identify the part, fix it or tell you honestly if the shower is due for replacement. See our bathroom repairs service or call 01462 506374, answered 24 hours a day, 7 days a week.

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.