Skip to main content

Vantage Plumbing and Heating

Sump Pump Problems: Signs of Failure and What to Do

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

A sump pump usually fails for one of five reasons: the power has gone off, the float switch has stuck, the pump or its inlet is clogged with silt or debris, the non-return valve has failed so water runs back in, or the discharge pipe outside is blocked or frozen. If the high-level alarm is sounding or water is rising in the sump, check the power and the outside discharge point first, stop using any drains that feed a sewage pump, and get an engineer out quickly, because a basement or cellar can flood in hours.

In short

  • Warning signs: the alarm sounding, the pump running non-stop, switching on and off rapidly, not starting, unusual noise, or water rising in the chamber.
  • Check the power, the RCD and the outside discharge point first. These are safe and fix a surprising number of failures.
  • A stuck float switch and a failed non-return valve are the most common mechanical faults.
  • Well designed systems have two pumps, a high-level alarm and a way to keep pumping in a power cut.
  • Pumps need regular servicing. A pump that is never checked tends to fail when it is needed most.
CCTV drain survey camera screen used by Vantage
The screen from one of our CCTV drain surveys.

What a sump pump does

A sump pump sits in a chamber, the sump, at the lowest point of a basement, cellar or below-ground room, and pumps out water that collects there. In UK homes you will usually find one of two kinds.

  • Groundwater sump pumps. Part of a basement waterproofing system, often a cavity drain membrane. Water that gets through the walls or floor is guided into channels and down to the sump, and the pump sends it out to a drain or soakaway.
  • Sewage or foul water pumping stations. Where a basement toilet, shower or utility room is below the level of the drain, waste runs into a sealed chamber and a pump lifts it up to the sewer. Approved Document H says a foul pumping installation should be sized to hold 24 hours of inflow, so there is time to deal with a failure.

In both cases a float switch senses the rising water level and starts the pump, and a non-return valve on the outlet stops pumped water running back in. Well designed systems have a primary and secondary pump and a high-level alarm that warns you if the water rises too far. Our drainage services team deals with the drains and discharge pipework these pumps depend on.

Signs your sump pump is failing

  • The high-level alarm is sounding. The water has risen above where the pump should have started. Treat this as urgent.
  • The pump runs constantly. Either water is coming in faster than it can pump, the float is stuck in the on position, or water is running back in through a failed non-return valve.
  • It switches on and off every few seconds. This short cycling is often a non-return valve problem or a float set too close to the pump.
  • It does not start at all. No power, a stuck float, a seized motor or a failed switch.
  • It hums but no water moves. The impeller or inlet is blocked, or the motor is failing.
  • Grinding, rattling or loud vibration. Debris in the impeller or worn bearings.
  • Damp, puddles or a smell in the basement. Water is getting past the system, or a sewage chamber is leaking or not sealed.

Check these first

These checks are safe for a homeowner and do not involve touching the pump or putting your hands in the water.

  1. Check the power. Is the pump’s socket or spur switched on? Has a breaker or RCD tripped on the consumer unit? If an RCD trips again immediately, leave it off and call an engineer, because a pump fault in water is an electrical hazard.
  2. Check the alarm. If the alarm has a battery, make sure it is working. Note whether it is showing a high water level or a fault.
  3. Look at the outside discharge point. Find where the pump’s outlet pipe discharges, often into a gully, drain or soakaway. Clear leaves or debris from a gully grating, and in freezing weather check the pipe end is not blocked with ice.
  4. Look into the sump without touching. With the lid off, is the water high? Is the float visibly jammed against the side of the chamber or tangled with a cable?
  5. For a sewage pump, stop using the fittings that feed it. Do not flush the basement toilet or run the shower or washing machine until it is working again.
  6. Test a groundwater pump if it looks normal. On a groundwater system, the installer’s guide may suggest pouring a bucket of clean water into the sump to check the pump starts and stops. Do not do this on a foul water pump.

Safety first

  • Water and electricity are a dangerous mix. Never put your hands into a sump while the pump has power.
  • Sewage chambers contain foul water and can hold harmful gases. Do not climb into or lean into a sewage chamber.
  • Do not try to take the pump apart or change the float settings yourself.
  • If water is entering living areas near sockets or appliances, switch off the power to that area at the consumer unit if it is safe to reach.

Common causes of sump pump failure

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Power cut or tripped RCDPump silent, alarm may soundReset once, if it holdsFinds why it tripped, checks the pump’s electrics
Float switch stuck or tangledPump never starts, or never stopsNoFrees or replaces the float and sets the switching levels
Clogged inlet or impellerHums but does not pump, or pumps slowlyNoLifts the pump, clears silt and debris, checks the impeller
Failed non-return valveShort cycling, water heard running backNoReplaces the valve
Blocked or frozen discharge pipePump runs but water level does not dropClear an outside gully onlyClears the pipe and the drain it discharges into
Pump too small for the inflowRuns constantly in wet weather, alarm in stormsNoChecks inflow and advises on pump capacity or a second pump
Worn-out pumpNoisy, slow, overheating, frequent tripsNoReplaces the pump
No backupFlooding in a power cut or when one pump failsNoAdvises on a second pump, battery backup and an alarm

Blocked drains beyond the pump

A pump can only work if the drain it discharges into is clear. If the pump is running but the water level barely drops, and the outlet pipe is clear, the problem may be in the drain or gully it empties into. Our drain blockage team can clear it, and a CCTV drain survey shows whether the pipe is damaged.

Preventing sump pump failure

  • Have the system serviced regularly. Follow the installer’s or manufacturer’s service interval, and do not let a system that protects living space go more than a year unchecked. A service checks the pumps, floats, valves and alarm, and clears silt from the chamber.
  • Check the alarm and replace its battery when needed.
  • Keep the outside discharge point clear of leaves and debris, especially in autumn.
  • Protect against power cuts. A battery backup or a second pump on a separate supply keeps pumping when the main pump cannot.
  • Keep the paperwork. Many basement waterproofing guarantees depend on the pumps being serviced. Check yours before anyone else works on a system still under guarantee.
  • For sewage pumps, only flush toilet paper. Wipes and sanitary products are a common cause of blockages in foul pumps.

Repair or replace?

Floats, non-return valves and alarms are straightforward parts to replace. A pump that is noisy, overheating or tripping the power, or one that has had a long, hard life, is often better replaced than repaired. If your system has only one pump and no backup, the time to fix that is before the next storm, not during it.

What it costs with Vantage

In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Frequently asked questions

Why is my sump pump running constantly?

Either water is coming in faster than usual, such as in prolonged heavy rain, or something is wrong: a float stuck in the on position, a failed non-return valve letting water run back, or a blocked discharge pipe. If the water level is not dropping while the pump runs, get it checked quickly.

What happens if a sump pump fails?

The water level in the chamber rises, and if nothing is done it overflows into the basement or cellar. With a foul water pump, that means sewage. A high-level alarm and a second pump are there to give you warning and time.

How long does a sump pump last?

It depends on how often it runs, what it pumps and how well it is maintained. Pumps that run often, or pump silty water, wear out sooner. Regular servicing is the best way to catch a pump that is nearing the end of its life.

Can I reset my sump pump?

You can reset a tripped breaker or RCD once, and some alarms have a reset or mute button. If the power trips again, or the pump still does not start, leave it for an engineer rather than resetting it repeatedly.

Who is responsible for a pumped drain?

A pump inside your property, serving only your home, is normally your responsibility. The drain it discharges into may be shared or public beyond your boundary. Our guide on who is responsible for clearing a blocked drain explains where the lines usually fall.

Help in Hertfordshire, Bedfordshire and Cambridgeshire

If your sump pump alarm is sounding or water is rising, check the power and the outside outlet, stop using any drains that feed a sewage pump, and call us. Our engineers can check the pump, clear the discharge pipe and the drains it feeds, and advise on what needs replacing. See our drainage services or our emergency drainage page, or call 01462 506374, answered 24 hours a day, 7 days a week.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.