Types of Radiator Valves Explained: TRVs, Manual and Lockshield

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

Most radiators have two valves: a control valve on one side that you turn to change the heat, and a lockshield valve on the other that an engineer sets once to balance the system. The control valve is either a thermostatic radiator valve (TRV), which turns the radiator down by itself as the room warms up, or a manual valve, which is simply on or off, and both come in angled, straight and corner shapes to suit how the pipes reach the radiator.

In short

  • Every radiator needs a control valve and a lockshield valve. They usually sit at opposite ends.
  • A thermostatic radiator valve (TRV) senses the room temperature and closes the valve as the room warms up. A manual valve does not.
  • The lockshield is set by an engineer to balance the flow, so every radiator heats evenly. You should not need to touch it.
  • The body shape (angled, straight, corner or H-block) depends on where the pipes come from, not on how the valve works.
  • When a boiler is replaced in England, building regulations guidance expects each room to have its own temperature control, which normally means TRVs.
Thermal image of a radiator heating evenly after a Vantage power flush
A thermal camera shot of a radiator heating evenly across its whole surface after a power flush.

Power flush price

Cold radiators or sludge? See your fixed price now

Tell us how many radiators you have and what your system is, and you get a fixed power flush price straight away, online.

Instant power flush priceOr call 01462 506 374

What a radiator valve does

A radiator is fed by two pipes: a flow pipe carrying hot water from the boiler and a return pipe taking cooler water back. A valve on each connection controls how much water can pass through.

The control valve is the one you use. It sets whether the radiator is on and, with a TRV, how warm the room gets. The lockshield valve limits the flow through that radiator so the water shares out fairly across the whole house. Without balancing, the radiators nearest the boiler take most of the flow and the ones at the far end stay lukewarm.

If you have a radiator that stays cold at the bottom, or one that never gets properly hot while the others are fine, the valves are one of the first things to check. Our guide to a radiator not heating up goes through the causes in order. If a valve is leaking or seized, our central heating repairs team can replace it and rebalance the system.

The main types of radiator valve

Thermostatic radiator valves (TRVs)

A TRV has a head with numbers on it, usually from a frost symbol or 0 up to 5 or 6. Inside the head is a sensor filled with wax, liquid or gas that expands as the air around it warms up. As it expands it presses a pin in the valve body, which gradually closes the valve and cuts the flow of hot water. When the room cools, the sensor contracts and the valve opens again.

The numbers are not temperatures. They are steps on a scale, and each manufacturer maps them slightly differently. Setting 3 is a common starting point for living rooms, with lower settings for bedrooms and rooms you use less.

TRVs save energy because rooms stop heating once they are warm enough, instead of every radiator running flat out until the main thermostat is satisfied. They work best alongside a room thermostat and a timer or smart control, not instead of them.

Manual valves

A manual valve (often called a wheelhead valve) is a simple tap. Turn it one way to open, the other way to close. It has no way of sensing the room, so the radiator runs at full output whenever the heating is on. Manual valves are cheap and reliable and are still fitted in the room that contains the main room thermostat, where a TRV would fight the thermostat.

Lockshield valves

The lockshield has a plain plastic cap that hides the spindle. It is adjusted with a small key or spanner during balancing and then left alone. If a lockshield has been fully closed by mistake, the radiator will stay cold no matter what you do to the control valve.

Smart TRVs

A smart TRV replaces the head of a standard TRV with a battery powered, motorised head. You set a temperature and schedule for each room from an app, and some systems can tell the boiler when a room needs heat. Most screw onto existing TRV bodies using an adapter, so you can often upgrade without draining the system. Check compatibility with your valve body and your heating controls first. Our smart thermostat installation service covers whole-house smart controls.

Bidirectional and flow-specific TRVs

Older TRVs had to be fitted on the flow pipe, with the water entering in one direction. Many modern TRVs are bidirectional, which means they can go on either the flow or the return pipe without causing noise. If a TRV hums, knocks or chatters, it may be fitted against its flow direction.

Valve body shapes

The shape of the valve body is about the pipe route, not the way the valve works. You can get TRVs, manual valves and lockshields in most of these shapes.

Valve shapePipe comes fromTypical use
AngledThe floor or wall, turning 90 degrees into the radiatorThe most common UK layout, pipes up through the floorboards
Straight (in-line)The side, in a straight line into the radiatorPipes running along the wall or skirting
CornerThe wall, with the valve body sitting against the radiator endNeat look where pipes come out of the wall
H-blockBoth pipes into one block under the radiatorMany designer and some panel radiators with a central connection
Twin entryBoth pipes through a single connectionMicrobore systems with a single inlet

Most UK valves are made for 15mm copper pipe with a half-inch connection to the radiator. Microbore systems use 8mm or 10mm pipe and need reducers or valves made for that size.

Do I need TRVs on every radiator?

In most homes, TRVs belong on every radiator except the one in the room with the main room thermostat. That room is the reference point for the whole house. If its radiator had a TRV, the valve could shut the radiator off before the thermostat is satisfied, and the boiler would keep running to heat the rest of the house.

When a boiler is replaced in England, building regulations guidance now expects each room to have its own thermostatic control, so the heat in each room can be adjusted separately. A room thermostat in one room and TRVs in the others is the usual way to meet it. There are some exceptions, for example open plan single storey homes where most of the floor area is one living space, and two adjoining rooms used in the same way, such as a kitchen and utility room, can be treated as one zone. A competent installer will check this as part of any boiler installation.

Common radiator valve problems

ProblemWhat you might noticeCan you fix it yourself?What the engineer does
Stuck TRV pinRadiator stays cold even on 5Sometimes: remove the head and gently free the pinFrees or replaces the valve
Lockshield closedRadiator cold, control valve openNot easily without knowing the original settingRebalances the system
Weeping gland or jointDamp patch, green or white crust on the valveNo, beyond checking it is not a loose capRepacks the gland or replaces the valve
Unbalanced systemNearest radiators hot, farthest ones lukewarmNoBalances every lockshield in turn
Noisy TRVHumming or knocking as it closesNoChecks flow direction, pump speed and bypass

A stuck TRV pin is very common after summer, because the pin sits still for months. With the head unscrewed, you can see the small metal pin in the valve body. If it is stuck down, a light tap or gentle wiggle can free it. Do not force it or grip it with pliers.

Sludge in the system makes valves stick and radiators heat unevenly. If several radiators are cold at the bottom, read our guide to power flushing and the signs your radiators need it.

What not to do

  • Do not unscrew a valve body or a joint with the system full of water. The water in a heating system is under pressure and dirty, and it will not stop.
  • Do not open a closed lockshield fully just to get heat. You will unbalance the rest of the house.
  • Do not fit a TRV in the room with the room thermostat.
  • If a valve starts leaking, put a towel and a container underneath and call a heating engineer.

Replacing a radiator valve

Swapping only a TRV head is often a simple job, because the body stays in place and no water escapes. Replacing a valve body is different. The engineer either drains the system down, or isolates and freezes the pipe, then fits the new valve, refills, bleeds and rebalances. On a sealed system the pressure also needs topping up and checking afterwards, and inhibitor should go back in.

Our central heating repairs engineers replace valves, free stuck ones and balance systems across Hertfordshire, Bedfordshire and Cambridgeshire. If you are replacing radiators at the same time, it is usually worth fitting new valves too.

How to choose radiator valves

  1. Decide on control. TRVs for every room except the thermostat room, or smart TRVs if you want room by room scheduling from an app.
  2. Match the pipe route. Angled for pipes from the floor, straight for pipes along the wall, corner for pipes from the wall.
  3. Check the pipe size. 15mm is standard. Microbore needs the right valve or reducers.
  4. Check the radiator connection. Designer radiators may need an H-block or a specific valve set from the maker.
  5. Match the finish. Chrome, white, black, brass and anthracite are common. Buy the TRV and lockshield as a matching pair.
  6. Think about hard water. Across most of Hertfordshire the water is hard, and a good quality valve with a sound seal tends to last better.

What it costs with Vantage

In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts, including valves, are quoted before we fit them. Replacing a valve body takes longer than swapping a head, because the system has to be drained or the pipe frozen, and then refilled and balanced. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Our work carries a 12 month labour guarantee.

Frequently asked questions

Which way do radiator valves open?

Turning the valve anticlockwise opens it and clockwise closes it on almost all UK radiator valves. On a TRV, turning to a higher number opens it further and turning towards the frost symbol or 0 closes it.

Should the TRV go on the flow or the return pipe?

A bidirectional TRV can go on either pipe. An older, single direction TRV should go on the flow pipe, and fitting it the wrong way round can cause knocking or humming as it closes.

Why is one radiator cold when the TRV is on full?

The TRV pin may be stuck closed, the lockshield may be shut, or the radiator may have air or sludge in it. Check the pin with the head removed and bleed the radiator. If it is still cold, an engineer can check the lockshield setting and the balance of the system.

Can I change a TRV head without draining the system?

Usually yes. The head unscrews from the valve body and the water stays in the pipes. Make sure the replacement head fits your valve body, or use the adapter supplied.

Do I need to balance radiators after changing valves?

Yes, if the lockshield was moved or a new one fitted. Balancing sets how much water each radiator receives, so the whole house heats evenly and the boiler runs efficiently.

Radiator valve repairs in Hertfordshire, Bedfordshire and Cambridgeshire

If a valve is leaking, stuck or you want TRVs fitted throughout, our own engineers can help from our Stevenage base. We are rated 4.9 on Google, and our phone is answered 24 hours a day, 7 days a week. See our central heating repairs page or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.