Why Is My Unvented Cylinder Losing Pressure?

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

An unvented cylinder that seems to be losing pressure usually has a problem on its cold water inlet, most often a blocked strainer or a failing pressure reducing valve, or it is simply passing on a drop in the mains supply. If you also see water dripping from the tundish or the discharge pipe outside, the expansion vessel or air gap has probably lost its charge, which needs an engineer but is rarely an emergency unless the water coming out is hot.

  • Check whether the cold taps are weak too. If they are, the problem is likely the mains or the inlet valve, not the cylinder itself.
  • A blocked inlet strainer or a worn pressure reducing valve are the most common causes of falling hot water pressure.
  • Cold water dripping into the tundish usually means the expansion vessel or air gap needs recharging.
  • Hot water running from the tundish is serious. Switch off the boiler and immersion heater and call an engineer.
  • Never adjust or tamper with the safety valves. Unvented cylinders must be worked on by a qualified engineer.
Unvented hot water cylinder installed by Vantage
An unvented hot water cylinder we installed.

How pressure works in an unvented cylinder

An unvented cylinder has no loft tank. Cold water comes straight from the mains into an inlet control group, which usually combines a strainer, a pressure reducing valve and a non-return valve. The pressure reducing valve lowers the mains to a steady working pressure that the cylinder is designed for. The mains then pushes hot water out of the cylinder whenever a tap opens, and a balanced cold supply feeds the cold taps and showers at the same pressure.

When the water heats, it expands. On most cylinders an expansion vessel, a small tank with a pressurised air cushion behind a membrane, takes up that extra volume. Some cylinders, including many Megaflo models, use an internal air gap instead. If the expansion space is lost, pressure rises every time the cylinder heats and the expansion relief valve opens to release it, sending water to the tundish.

So “losing pressure” can mean two quite different things:

  1. Weak flow at the taps and showers. Usually a supply or inlet problem.
  2. Water escaping from the system. Usually a relief valve discharging, or a leak.

For more on how these systems are put together, see our unvented cylinder service page.

Check these first

These checks are safe for a homeowner and will tell your engineer a great deal.

  1. Compare hot and cold. Run a cold tap and a hot tap in the same room. If both are weak, the problem is upstream of the cylinder. If only the hot is weak, it is more likely the cylinder side.
  2. Check other outlets. Is it one shower or the whole house? A single weak shower is often a scaled showerhead or a mixer cartridge, not the cylinder.
  3. Ask the neighbours or check your water supplier. A local mains problem or burst will affect everyone nearby.
  4. Check the stopcock. Make sure your main stopcock is fully open. Stopcocks are sometimes left partly closed after other work.
  5. Look at the tundish. It is the small open funnel on the pipework near the cylinder. Is it dry, dripping cold water, or running hot water?
  6. Look at the discharge pipe outside. It usually ends low on an outside wall or over a gully. Any sign of water or staining is worth noting.
  7. Note when it happens. Weak only at busy times points to supply flow. Dripping from the tundish while the cylinder heats points to expansion.

If the whole house has weak water, our guide to low water pressure in the whole house covers the supply side in more detail.

What not to do

  • Do not adjust, cap, block or remove any safety valve, the tundish or the discharge pipe.
  • Do not try to reset or bypass the thermal cut-out repeatedly.
  • If hot water or steam is coming from the tundish, switch off the boiler and immersion heater straight away and call an engineer.
  • Do not unscrew the inlet valve or strainer yourself with the system under mains pressure.
  • Unvented systems must be worked on by an engineer qualified for unvented hot water.

Common causes

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Blocked inlet strainerHot and balanced cold outlets gradually weaker, often after mains workNoIsolates the supply, removes and cleans the strainer, flushes debris
Faulty pressure reducing valvePressure fluctuates, drops when several outlets open, sometimes creeps up overnightNoTests inlet and outlet pressure, replaces the valve or its cartridge
Low mains pressure or flowHot and cold both weak, worse at busy timesReport it to your water supplier if it is localMeasures pressure and flow at the stopcock and outlets, advises on supply options
Expansion vessel lost its chargeCold water dripping into the tundish as the cylinder heats, pressure spikesNoIsolates and drains down, recharges the vessel or replaces it if the membrane has failed
Internal air gap lost (air gap cylinders)Similar dripping from the tundish while heatingNoRestores the air gap following the manufacturer’s procedure
Expansion relief valve letting byConstant slow drip into the tundish even when the cylinder is not heatingNoChecks the pressure first, then replaces the valve if it is worn or scaled
Temperature and pressure relief valve dischargingHot water from the tundish, cylinder very hotNo, switch off and callChecks the thermostat, cut-out and motorised valve, replaces faulty parts
Leak on pipework or a fittingDamp patches, water marks, running meter with taps offIsolate if you can see itFinds and repairs the leak

Which causes are most likely?

Falling pressure on an unvented cylinder most often comes down to the inlet control group. The strainer catches debris from the mains, especially after the water supplier has carried out work in the road. Hard water adds scale over the years. A pressure reducing valve that is starting to fail can give strong pressure one day and weak the next.

Tundish dripping is the second big group. It is often the first sign that the expansion vessel needs recharging, and annual servicing usually catches it before it starts.

Genuine problems with the cylinder body itself are much less common.

Is my mains supply good enough?

An unvented cylinder can only deliver what the mains gives it. Manufacturers publish the supply they recommend. Gledhill, for example, recommends 3 bar and 30 litres per minute for optimum performance from its StainlessLite Plus cylinders, and says performance falls off with lower figures.

Pressure and flow are different. A supply can show a decent static pressure with the taps shut, then fall away sharply when two showers run. An engineer measures both. If the supply itself is the problem, options include a larger supply pipe or boosting the supply with a correctly sized system.

What an engineer will check

A proper diagnostic on an unvented cylinder usually covers:

  • the static and working pressure and the flow rate at the incoming supply
  • the pressure after the pressure reducing valve, to see whether it is holding its setting
  • the inlet strainer, cleaned and inspected
  • the expansion vessel charge, tested with the cylinder side isolated and drained down, or the air gap on cylinders that use one
  • the expansion relief valve and the temperature and pressure relief valve, checked for letting by
  • the tundish and the discharge pipe route
  • the cylinder thermostat, thermal cut-out and the motorised valve that controls the boiler’s heat to the cylinder
  • any visible leaks on the pipework around the cylinder

If the heating works but you have lost hot water altogether, that is a different fault. Our guide to no hot water but the heating works covers it.

Preventing pressure problems

  • Service it every year. Manufacturers recommend an annual service for unvented cylinders. It is when strainers are cleaned and the expansion charge is restored.
  • Deal with hard water. Scale builds up in valves and on heating coils. A water softener protects the cylinder and the rest of your plumbing.
  • Watch the tundish. A quick look when you pass the airing cupboard catches problems early.
  • Know your stopcock. Make sure it turns and is fully open.

Repair or replace?

Most pressure problems are fixed by cleaning or replacing a valve, or by recharging the expansion vessel. Replacement of the whole cylinder only makes sense if the cylinder itself is leaking, the coil has failed, or it is old, undersized for your household and needing repeated repairs. If you are replacing it, it is worth measuring the supply first so the new cylinder is matched to it.

What it costs with Vantage

In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts, such as a pressure reducing valve or an expansion vessel, are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

New cylinder installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Frequently asked questions

Why is my tundish dripping?

A cold drip into the tundish while the cylinder heats up is most often a lost expansion charge or an expansion relief valve that is letting by. It is not an emergency, but book an engineer soon because the valve will wear faster. Hot water from the tundish is serious: switch off the heat sources and call straight away.

Why is the hot water pressure lower than the cold?

On a correctly installed unvented system, hot and cold outlets fed from the balanced supply should be similar. If the hot is noticeably weaker, suspect a partly blocked strainer, a failing pressure reducing valve, a scaled mixer valve or a pipework restriction on the hot side.

Can I top up the pressure on an unvented cylinder like a boiler?

No. There is no filling loop to top up on the cylinder itself, because it runs from the mains. Pressure problems come from the supply, the inlet valves or the expansion arrangement, and all of those need a qualified engineer.

Does the expansion vessel on my cylinder need checking?

Yes. The air charge in an expansion vessel slowly drops over time, and it is checked and restored as part of an annual service. If the vessel’s membrane has failed, it will need replacing.

Why did my pressure drop after the water board worked in the street?

Mains work can stir up debris that is caught by the strainer on your cylinder’s inlet, reducing the flow. Cleaning the strainer usually restores it. If the pressure stays low, the engineer will check the supply itself.

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Unvented cylinder help in Hertfordshire, Bedfordshire and Cambridgeshire

If your unvented cylinder has lost pressure or the tundish is dripping, our engineers can find the cause and fix it. See our unvented cylinder service or call 01462 506374, answered 24 hours a day, 7 days a week, with 24/7 emergency cover.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.