Unvented Cylinder Servicing: Why It Matters and What It Involves
Hertfordshire, Bedfordshire & Cambridgeshire
An unvented hot water cylinder should be serviced once a year by a qualified engineer, because it stores hot water at mains pressure and relies on safety valves and cut-outs that need testing to prove they still work. Manufacturers recommend annual maintenance, and most make regular servicing by a competent person a condition of the cylinder’s guarantee.
In short
- Unvented cylinders hold hot water under mains pressure, so their safety devices must work every time.
- Manufacturers recommend annual maintenance by a competent, suitably qualified person.
- A service tests the relief valves, checks the expansion vessel, cleans the inlet strainer and checks the controls and discharge pipework.
- Skipping servicing can put the manufacturer’s guarantee at risk.
- Water from the tundish or the discharge pipe outside is a sign something needs attention.

What an unvented cylinder is
An unvented cylinder is a sealed hot water tank fed directly from the cold mains, with no tank in the loft. Well-known examples include the Megaflo, but many manufacturers make them. Because the stored hot water is at mains pressure, you get strong showers and good flow to several taps at once. It is the usual partner for a system boiler in homes with more than one bathroom.
That pressure is also why the cylinder needs looking after. A traditional vented cylinder has an open pipe to a loft tank, so it can never build up pressure. An unvented cylinder is sealed, so it depends on a set of safety devices to stop the water getting too hot or the pressure getting too high. Building Regulations in England require any hot water storage system to have precautions that stop the stored water ever exceeding 100°C and to discharge any water from its safety devices somewhere visible where it will not endanger anyone. Our unvented cylinder service covers installation, servicing and repairs.
The safety devices a service checks
| Part | What it does | What goes wrong |
|---|---|---|
| Cylinder thermostat | Controls the stored water temperature | Can drift or fail, giving water too hot or too cool |
| High-limit thermal cut-out | Cuts the heat source if the thermostat fails | Can trip or fail, leaving no hot water |
| Temperature and pressure relief valve | Opens to release water if temperature or pressure gets too high | Scale can stop it seating, causing a constant drip |
| Expansion relief valve | Releases pressure if the expansion vessel cannot cope | Drips or discharges when the vessel loses its charge |
| Expansion vessel or air gap | Absorbs the water’s expansion as it heats | Loses its air charge over time |
| Pressure reducing valve and strainer | Sets the incoming mains to the right pressure and filters debris | Strainer blocks, cutting flow, or pressure creeps up |
| Tundish and discharge pipe | Lets you see any discharge and carries it safely outside | Can be blocked, badly routed or hidden |
What an unvented cylinder service involves
The exact steps depend on the make and model, and the manufacturer’s instructions set them out. A typical annual service follows this pattern:
- Visual inspection. The engineer checks the cylinder, valves and pipework for leaks, corrosion and signs of past discharge.
- Relief valve tests. Each relief valve is opened manually for a few seconds to check water flows freely through the tundish and discharge pipe, and that the valve reseats and stops fully afterwards.
- Expansion vessel check. The vessel’s air charge is checked and topped up if it has dropped. On cylinders that use an internal air gap instead, the air gap is recharged using the manufacturer’s procedure.
- Strainer clean. With the mains isolated and the pressure relieved, the strainer in the inlet valve is removed, cleaned and refitted.
- Inlet pressure. The incoming pressure after the pressure reducing valve is checked against the manufacturer’s figure.
- Controls. The cylinder thermostat, the high-limit cut-out and any immersion heater controls are checked for correct operation.
- Immersion heater. In hard water areas the immersion heater can scale up. Where the manufacturer recommends it, the element is checked and descaled.
- Discharge pipework. The tundish and the route of the discharge pipe are checked to make sure any discharge would be visible and safe.
- Paperwork. The service is recorded, usually on the Benchmark service record that came with the cylinder, which you need for any guarantee claim.
Hard water across most of Hertfordshire makes steps 2, 4 and 7 more important, because scale is what stops relief valves seating and blocks strainers. If scale is a constant problem, our water softener installation service may be worth a look.
Why servicing matters
Safety
The safety devices are there for the one day something else goes wrong. A relief valve that has scaled up, or a cut-out that has failed, may not act when needed. The only way to know they work is to test them.
Your guarantee
Manufacturers typically make the cylinder guarantee conditional on regular maintenance by a competent person, recorded in the Benchmark service record. If a cylinder fails and there is no service history, the claim may be refused.
Performance and running costs
A blocked strainer cuts the flow to every hot tap. A cylinder with a flat expansion vessel can discharge water outside every time it heats, wasting water and energy. A scaled immersion heater takes longer to heat the water.
Warning signs to watch for between services
- Water dripping or running through the tundish. The funnel near the cylinder should normally be dry.
- Water coming from the discharge pipe outside, often a short pipe near the ground or into a gully.
- Hot water pressure that rises or falls sharply when the cylinder heats up.
- Weak flow at the hot taps compared with the cold.
- No hot water, but the heating works. This can be a tripped cut-out or a faulty valve. Our guide to no hot water but heating works covers the other common causes.
- Banging or knocking from the pipework, which our guide to banging pipes and water hammer explains.
If hot water is discharging from the tundish or outside pipe
- Switch off the boiler and any immersion heater so the cylinder stops heating.
- Do not touch the discharge pipe or the water. It may be very hot.
- Do not try to cap or block the discharge pipe or the tundish, ever.
- Do not dismantle the valves yourself. Call an engineer.
- If the boiler is also showing faults and you smell gas, call the National Gas Emergency Service on 0800 111 999.
Who should service an unvented cylinder?
Manufacturers state that maintenance should only be carried out by a suitably qualified, competent person. For unvented cylinders that normally means an engineer who holds a specific unvented hot water qualification, in addition to any Gas Safe registration for the boiler. When you book, ask whether the engineer is qualified to work on unvented systems.
For landlords, note that a gas safety record covers gas appliances such as the boiler. It does not include a service of the cylinder’s safety valves, so book that separately. Our landlord services page explains what we can arrange for rental properties.
What it costs with Vantage
In normal working hours there is no call-out fee. Cylinder servicing and repairs are charged at our published rates: after the first hour, time is charged in half-hour steps, and any parts, such as a replacement valve cartridge or expansion vessel, are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. If you have a system boiler, you can ask for the cylinder service to be booked alongside your annual boiler service.
Frequently asked questions
How often should an unvented cylinder be serviced?
Once a year is what manufacturers recommend. Annual maintenance by a competent person is also usually a condition of the cylinder’s guarantee, so keep the service record safe.
Can I service my own unvented cylinder?
No. Manufacturers state maintenance should be done by a suitably qualified person, and the work involves isolating the mains, relieving pressure and testing safety valves on a vessel holding very hot water under pressure. You can keep an eye on the tundish and tell an engineer if it is ever wet.
Why is my unvented cylinder dripping into the tundish?
The most common reasons are a flat expansion vessel, a relief valve that is not seating because of scale or debris, or incoming pressure that is too high. All three are checked at a service. A constant drip is a sign it needs attention soon, not something to leave.
How long does an unvented cylinder last?
A well-maintained unvented cylinder can last many years, and many carry long guarantees on the vessel itself. The valves and expansion vessel are the parts that wear, and they can usually be replaced without changing the cylinder.
Is a boiler service the same as a cylinder service?
No. A boiler service covers the boiler and its gas safety checks. The cylinder’s relief valves, expansion vessel and strainer are separate items with their own checks, so ask for both if you have a system boiler with an unvented cylinder.
Unvented cylinder help in Hertfordshire, Bedfordshire and Cambridgeshire
If your cylinder has not been serviced in the last year, or the tundish is showing water, it is worth booking a check. We service and repair unvented cylinders across Hertfordshire, Bedfordshire and Cambridgeshire, and our phone is answered 24 hours a day, 7 days a week. See our unvented cylinder service page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374