What Are Thermostatic Radiator Valves and Do I Need Them?
Hertfordshire, Bedfordshire & Cambridgeshire
Thermostatic radiator valves (TRVs) are the numbered valves on the side of a radiator that sense the air temperature in the room and automatically cut the flow of hot water when the room reaches the level you set. Most homes with central heating should have them, because they let you heat each room to a different temperature and stop rooms overheating, which saves energy and makes the whole system more comfortable.
- A TRV has a sensing head and a valve body. The head expands as the room warms and closes the valve.
- The numbers are a comfort scale, not exact degrees. Around 3 suits most living rooms.
- Turning a TRV to maximum does not heat the room faster. It only changes where it stops.
- Do not fit a TRV in the same room as the main room thermostat, or set it higher than the thermostat.
- A TRV that will not open after the summer usually has a stuck pin, which is often an easy fix.

Power flush price
Cold radiators or sludge? See your fixed price now
Tell us how many radiators you have and what your system is, and you get a fixed power flush price straight away, online.
How a thermostatic radiator valve works
A TRV has two parts.
- The head. This is the part with the numbers. Inside is a sensor, usually a wax plug or a liquid or gas filled capsule, that expands as the air around it warms and contracts as it cools.
- The valve body. This is the brass part screwed onto the radiator pipe. It has a small spring-loaded pin that sticks up into the head.
As the room warms, the sensor in the head expands and pushes the pin down, gradually closing the valve and reducing the flow of hot water into the radiator. As the room cools, the sensor contracts, the pin springs back up and more hot water flows in. It is a simple, self-contained control with no wiring or batteries.
The valve on the other end of the radiator is usually a lockshield valve, with a plain plastic cap. That one is not for everyday use. An engineer sets it when the system is balanced, so that each radiator gets its fair share of flow. Leave it alone unless you know what you are doing. If some radiators heat well and others barely warm, our central heating repairs engineers can balance the system properly.
What the numbers on a TRV mean
The numbers are a relative comfort scale. They are not degrees, and the exact temperature each number gives varies between makes and depends on where the radiator is. As a rough guide:
| Setting | Roughly suits | Typical use |
|---|---|---|
| Snowflake or asterisk | Frost protection only | Empty rooms, holidays |
| 1 | A cool room | Rarely used spaces, hallways |
| 2 | A cool bedroom | Bedrooms for people who like it cool |
| 3 | A comfortable living temperature | Living rooms, most rooms |
| 4 | Warmer than average | Rooms used by older people or babies |
| 5 | Fully open | Very cold rooms, or checking the radiator works |
The Energy Saving Trust suggests setting each TRV to the lowest setting that keeps the room comfortable, and keeping your main thermostat at the lowest comfortable temperature, which for most people is between 18 and 21 degrees.
Do I need thermostatic radiator valves?
For most homes with a gas or oil boiler and radiators, yes. Here is why.
- Room by room control. Bedrooms can run cooler than the living room, and rooms you rarely use do not need to be as warm.
- No overheating. Rooms that warm up quickly, such as a south-facing room or a kitchen, stop taking heat once they are warm.
- Less wasted energy. Hot water goes to the rooms that need it rather than to rooms that are already warm.
- Current standards expect them. TRVs are the usual way of giving each room its own temperature control, and when you replace a boiler the installer will check your controls meet building regulations. Since April 2018, every new gas boiler in England must have time and temperature controls fitted with it.
TRVs work best alongside a room thermostat and a timer or programmer, not instead of them. The room thermostat tells the boiler when the house as a whole is warm enough, and the TRVs fine tune each room. If your controls are old or missing, our smart thermostat installation page explains the modern options.
Where not to fit a TRV
- The room with the main thermostat. If the TRV closes before the thermostat is satisfied, the thermostat keeps calling for heat and the boiler runs on. Leave that radiator on a manual valve, or set its TRV higher than the room thermostat.
- Behind curtains, furniture or radiator covers. The head will sense trapped warm air and close too early.
- Where the system relies on it for a bypass. Many systems have one radiator, often in the bathroom or hall, left without a TRV so there is always somewhere for water to flow. Others use an automatic bypass valve. If you are fitting TRVs to every radiator, have an engineer check the bypass arrangement for your boiler.
Types of TRV
| Type | How it works | Good for |
|---|---|---|
| Standard (wax or liquid head) | Mechanical, no power | Most homes, low maintenance |
| Remote sensor head | Sensor on a cable, away from the radiator | Radiators behind furniture or under windowsills |
| Tamper-proof or limiting head | Setting can be locked or limited | Landlords, schools, care settings |
| Smart TRV | Battery-powered electronic head, set by app or schedule | Room by room timing, zoning without new pipework |
Many modern valve bodies are bidirectional, meaning they can go on either end of the radiator. Some older valves must be fitted on the flow side only, so check before swapping heads between makes.
Common TRV problems and what to do
Radiator cold with the TRV on 5
The most common cause, especially in autumn, is a stuck pin. After months closed over the summer, the pin in the valve body can seize in the down position.
Check these first:
- Turn the TRV to 5 and make sure the heating is on and calling for heat.
- Feel the pipe on the other end of the radiator. If only the TRV end is warm, the valve is not opening.
- Remove the head. Most unscrew or unclip by hand when set to maximum. Your valve maker’s instructions show how.
- Look at the pin. If it is flush or pushed down, press it gently a few times with something smooth. It should spring back up.
- Refit the head and wait for the radiator to warm.
If the radiator is warm at the bottom but cold at the top, it needs bleeding rather than a new valve. Our guide on how to bleed a radiator walks you through it, and our radiator not heating up guide covers the other causes.
What not to do
- Do not use pliers to force the pin or hit the valve body. A broken pin or cracked body means water under pressure.
- Do not unscrew the valve body itself or the nuts on the pipe. That part is full of system water and needs the system drained or isolated.
- Do not turn the lockshield valve to “fix” a cold radiator. It will unbalance the system.
- If water is leaking from the valve, turn the TRV and lockshield off, put a towel down and call a plumber.
Radiator stays hot when the room is warm
The head may be faulty, the sensor may be sensing a cold draught, or the valve may not be closing fully. Try a different head of the same make. If the radiator still does not respond, the valve body may need replacing.
Water weeping from the valve
A small weep from around the pin can sometimes be cured by replacing the valve’s gland seal. A leak from the pipe nuts or the body needs repair. Leaks left alone lower the system pressure and let fresh water in, which causes corrosion. If your boiler is also losing pressure, check every valve for damp.
Can you replace a TRV yourself?
Swapping just the head is simple and usually needs no tools, as long as the new head fits the valve body. Replacing the valve body is a plumbing job. The system has to be drained down, isolated or pipe-frozen, the old valve removed, a new tail fitted and sealed, and the system refilled, bled and repressurised. If inhibitor is lost while draining, it should be topped up. Our central heating repairs engineers replace TRVs and lockshield valves every week, and it is often worth doing several radiators at once while the system is drained.
What it costs with Vantage
In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts such as new valves are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
Changing a head costs less than changing a valve body, and replacing several valves on one visit is more efficient than doing them one at a time, because the system only needs draining once. All our work carries a 12 month labour guarantee.
Frequently asked questions
Is it worth fitting thermostatic radiator valves?
In most homes, yes. They stop rooms overheating and let you run cooler bedrooms and unused rooms, so less energy is wasted. The Energy Saving Trust recommends setting each one to the lowest setting that keeps the room comfortable.
Can you replace a TRV without draining the system?
You can change the head without draining, because it sits outside the water. Replacing the valve body needs the system drained, isolated or the pipe frozen, so it is a job for a plumber or heating engineer.
How do I know if my TRV is working?
Turn it to 5 with the heating on. The radiator should warm within a few minutes. Then turn it down to 1. After the room warms, the radiator should cool noticeably. If nothing changes either way, the pin is probably stuck or the head is faulty.
How long do thermostatic radiator valves last?
There is no fixed lifespan. Many last for years, but pins can stick, heads can lose their sensitivity and seals can weep. Replacing old TRVs is often worth doing when a boiler is replaced or the system is being cleaned.
Should TRVs be on every radiator?
Usually on every radiator except the one in the room with the main room thermostat. Your boiler may also need a bypass, either an automatic bypass valve or one radiator left open, so have an engineer check before fitting TRVs everywhere.
When to call an engineer
If a radiator stays cold after freeing the pin, a valve is leaking, or you want TRVs fitted throughout the house, our heating engineers can help. See our central heating repairs service or call 01462 506374, answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Power flushing near you
Sludge or cold radiators? We flush heating systems across the area
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374