What Is a Megaflo System? How Unvented Hot Water Works

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

A Megaflo system is a heating and hot water setup built around a Megaflo unvented hot water cylinder, which stores hot water fed directly from the mains, so every tap and shower gets hot water at mains pressure without a cold water tank in the loft. Megaflo is Heatrae Sadia’s brand, and it is so well known that many people, and many searches spelt “Megaflow”, use the name for any unvented cylinder.

  • A Megaflo is an unvented cylinder: a sealed, stainless steel hot water store fed straight from the mains.
  • It gives strong showers and fast-filling baths at several outlets at once, as long as your mains supply is good.
  • It is usually paired with a system boiler or a regular boiler, and can be heated by an immersion heater.
  • Because it runs under pressure, it has several safety valves and must be installed by a competent, qualified installer.
  • Megaflo recommends an annual service. The stored hot water can run out and takes time to reheat.

How a Megaflo system works

An older, vented hot water system relies on gravity. A cold water tank in the loft feeds a copper cylinder, and the pressure at your taps depends on how high that tank sits above them. That is why showers on a tank-fed system are often weak without a pump.

An unvented cylinder like a Megaflo takes the tank out of the picture. Cold water comes straight from the mains, through a set of valves that control its pressure, into a sealed cylinder. The water is heated and stored there. When you open a hot tap, the mains pressure pushing in at the bottom pushes hot water out at the top, so the hot water arrives at close to mains pressure. Your cold taps are fed from the mains as well, so hot and cold are balanced.

The water can be heated in two ways:

  • Indirect cylinders have a coil inside. Hot water from a boiler (or a heat pump, with a cylinder designed for it) flows through the coil and heats the stored water without mixing with it. Most also have an immersion heater as a backup.
  • Direct cylinders are heated by electric immersion heaters alone, which suits homes without a gas boiler.

A typical Megaflo system in a home with a gas boiler means a system boiler (which has its pump and expansion vessel built in) or a regular boiler, a Megaflo cylinder, and a motorised valve or two that send the boiler’s heat to the radiators, the cylinder, or both.

Where does the expansion go?

Water expands as it heats. In a vented system, the extra volume goes back up to the loft tank. In a sealed cylinder it needs somewhere else to go. Many unvented cylinders use an external expansion vessel. Megaflo introduced an internal air gap with a floating baffle in 1988, and most of the current Megaflo Eco range still uses internal expansion, so it does not need a separate vessel. The air gap is checked and restored as part of a service.

The safety devices on an unvented cylinder

A cylinder full of hot water under mains pressure is safe when properly installed, because several independent devices stop the temperature or pressure going too high. The Building Regulations require precautions that stop stored water ever exceeding 100°C and that carry any discharge from the safety devices to somewhere it is visible but not dangerous.

DeviceWhat it does
Cold water combination valveReduces and steadies the incoming mains pressure, and stops water flowing back into the mains
Expansion relief valveOpens if the pressure in the cylinder rises too high, for example if the expansion space is lost
Control thermostatSets the normal stored water temperature
Thermal cut-outA separate high-limit device that shuts off the heat source if the thermostat fails
Temperature and pressure relief valveThe last line of defence. Opens to release water if the temperature or pressure becomes dangerous
Tundish and discharge pipeLets you see if any valve is discharging, and carries the water safely outside

The Megaflo Eco range

Megaflo’s current range is the Megaflo Eco. Heatrae Sadia lists direct, indirect, slimline, solar, Solar PV Ready, SystemFit and SystemReady versions, most of them with 60mm of insulation, and a 30-year warranty on the stainless steel inner tank. Check the terms for your model, and register it, because warranty conditions apply.

Our unvented cylinder service covers installing, servicing and repairing unvented cylinders, including Megaflo, and we will size the cylinder to your household rather than to a brochure.

Megaflo system, combi boiler or vented cylinder?

Megaflo (unvented) systemCombi boilerVented cylinder system
Hot water pressureClose to mains pressureMains pressureDepends on tank height, often low
Several outlets at onceYes, if the mains flow is goodStruggles with more than one outletYes, but pressure drops
Can hot water run out?Yes, once the stored volume is usedNo, heated as you use itYes
Loft tank neededNoNoYes
Space neededCylinder cupboard and a discharge pipe routeNone beyond the boilerCylinder cupboard and loft tank
Best suited toTwo or more bathrooms, good mains supplySmaller homes, one bathroomLow mains pressure, simple systems

If you are comparing options for a smaller home, our guide to the best combi boilers covers the other route.

Advantages and disadvantages

Advantages

  • Strong showers and fast-filling baths without a pump
  • Several showers and taps can run at the same time
  • No cold water storage tank in the loft for your taps and showers, which frees up space
  • Works with gas boilers, heat pumps, solar and immersion heaters
  • A stainless steel inner tank with a long manufacturer warranty

Disadvantages

  • Only as good as your mains supply. Weak mains pressure or flow means weak hot water
  • The stored hot water can run out, and then needs time to reheat
  • Needs space for the cylinder and a safe route for the discharge pipe
  • Must be installed by a qualified installer and should be serviced every year
  • Some heat is lost from the cylinder even with good insulation

Is a Megaflo right for your home?

Before recommending one, a good installer will check:

  1. Mains pressure and flow. Measured at the property. An unvented cylinder cannot improve a poor supply. If flow is the problem, see our guide to low water pressure in the whole house.
  2. How much hot water you use. The number of bathrooms and people decides the cylinder size.
  3. Where it will go. The cylinder, its valves and the discharge pipe all need space, and the discharge pipe must run to a safe, visible outlet.
  4. The heat source. Existing boiler, a new system boiler, or a heat pump, which needs a cylinder designed for it.
  5. Water hardness. Hard water, common across Hertfordshire, scales up coils and immersion heaters over time. A water softener protects the cylinder and everything downstream.

If you are replacing the boiler at the same time, our boiler installation team can design the whole system together.

Installation and servicing rules

Because unvented systems work under pressure, Building Regulations guidance says they must be installed by a competent person, typically an installer with an unvented hot water qualification, and the installation must be notified to building control. Megaflo recommends that its products are serviced annually. A service checks the valves, the expansion space, the thermostats and cut-out, and the discharge pipe.

Safety first

  • Never adjust, cap or remove the safety valves or block the discharge pipe or tundish.
  • If hot water is running continuously from the tundish or discharge pipe, switch off the boiler and the immersion heater and call an engineer straight away.
  • A small drip of cold water from the tundish usually means the expansion space or the expansion relief valve needs attention. It is not an emergency, but book it in soon.
  • Do not try to fit or move an unvented cylinder yourself. It is not legal without the right competence.

Common problems

What you noticeLikely cause
Cold water dripping into the tundish, often when heating upExpansion space lost or the expansion relief valve letting by
Hot water discharging from the tundishOverheating or high pressure. Switch off the heat sources and call an engineer
No hot waterThermostat, a tripped thermal cut-out, a motorised valve, the programmer or the immersion heater
Poor pressure at all outletsA blocked strainer in the inlet valve, a pressure reducing valve fault or a poor mains supply
Hot water runs out quicklyThe cylinder is too small for demand, or the coil is scaled or not heating fully

How we price it

Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay.

For repairs, there is no call-out fee in normal working hours. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Frequently asked questions

Is a Megaflo better than a combi boiler?

It depends on the house. A Megaflo suits homes with two or more bathrooms and a good mains supply, where several people use hot water at once. A combi suits smaller homes and never runs out of hot water, but struggles to supply more than one outlet at a time.

Why is it called Megaflow?

The brand is spelt Megaflo, and it belongs to Heatrae Sadia. “Megaflow” is a common misspelling, and the name is widely used for any unvented cylinder, whatever the make.

Does a Megaflo need servicing?

Yes. Megaflo recommends an annual service for all its products. The safety valves, expansion space, thermostats and discharge pipe all need checking to keep the cylinder safe and working properly.

Can a Megaflo work with a heat pump?

A heat pump needs a cylinder designed for it, with a larger coil because heat pumps run at lower temperatures. Ask for a cylinder matched to the heat pump rather than reusing one designed for a gas boiler.

Why is my Megaflo tundish dripping?

A drip of cold water usually means the internal air gap needs restoring or the expansion relief valve is letting by, both of which an engineer can sort out. Hot water running from the tundish is more serious: switch off the heat sources and call an engineer.

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Help in Hertfordshire, Bedfordshire and Cambridgeshire

Whether you are thinking about a Megaflo or your existing cylinder is dripping, losing pressure or not heating, our engineers can help. See our unvented cylinder service or call 01462 506374, answered 24 hours a day, 7 days a week.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.