What Is a Room Thermostat and How Does It Work?
Hertfordshire, Bedfordshire & Cambridgeshire
A room thermostat is the wall-mounted control that senses the air temperature and tells your boiler to heat the house until it reaches the temperature you set, then switches the heating off until the room cools slightly. It controls how warm the house gets, while the timer or programmer controls when the heating is allowed to run, and most people are comfortable with it set between 18 and 21 degrees.
- A room thermostat measures the air temperature and switches the heating on or off to hold your chosen setting.
- It controls temperature. The timer controls when the heating is on. TRVs fine tune individual rooms.
- Turning it up does not make the house heat faster. It only makes it stop at a higher temperature.
- Fit it on an inside wall away from radiators, sunlight, draughts and kitchens, and do not put a TRV in the same room.
- Every new gas boiler in England must be fitted with time and temperature controls.
How a room thermostat works
A room thermostat contains a temperature sensor. Older dial thermostats use a mechanical element that moves as it warms and cools, while digital and smart thermostats use an electronic sensor.
- You set the temperature you want, for example 20 degrees.
- When the room is below that, the thermostat closes a switch and sends a call for heat to the boiler, or to a motorised valve that then fires the boiler.
- The boiler heats the water and the pump sends it round the radiators.
- When the room reaches the set temperature, the thermostat opens the switch and the boiler stops heating.
- When the room cools a little below the setting, it calls for heat again.
That small gap between switching off and on again stops the boiler cycling on and off every few seconds.
Some modern thermostats go further. Instead of just switching the boiler on and off, a load compensating thermostat talks to the boiler and turns its flow temperature down as the room gets close to the target. The boiler runs longer at a lower, more efficient temperature, which suits condensing boilers well. Our smart thermostat installation service fits both simple and smart controls.
Room thermostat, timer, TRVs and the boiler dial: what does what
People often confuse these, and it leads to wasted gas or a cold house.
| Control | What it controls | Where it is |
|---|---|---|
| Room thermostat | How warm the house gets | On a wall in a main room or hallway |
| Timer or programmer | When the heating and hot water are allowed to run | On the boiler or a separate unit, sometimes built into the thermostat |
| Thermostatic radiator valves (TRVs) | How warm each individual room gets | On each radiator |
| Boiler heating dial | How hot the water sent to the radiators is (flow temperature) | On the boiler |
| Cylinder thermostat | How hot the stored hot water gets | On the hot water cylinder, if you have one |
The room thermostat and the boiler’s flow temperature dial do different jobs. Turning the boiler dial right up does not make the room warmer in the end, it just makes the radiators hotter and the boiler less efficient.
Types of room thermostat
| Type | How you set it | Good for |
|---|---|---|
| Dial (mechanical or electronic) | Turn a dial to a temperature | Simple, reliable temperature control with a separate timer |
| Digital | Buttons and a display | Easier to set precisely |
| Programmable | Different temperatures at different times of day | Replacing a separate timer, lower temperatures overnight |
| Wireless | Battery thermostat that talks to a receiver near the boiler | Moving the thermostat to a better spot without new wiring |
| Smart | App, schedule and sometimes automatic features such as geolocation | Remote control, learning schedules, multi-zone homes |
| Load or weather compensating | Adjusts the boiler’s flow temperature, not just on and off | Getting the most from a condensing boiler |
Since April 2018, all new gas boilers in England must be fitted with time and temperature controls. A replacement combi boiler must also have one extra energy-saving measure, and a smart thermostat with automation and optimisation features is one of the options, along with load compensation and weather compensation.
Where to put a room thermostat
Where the thermostat sits matters as much as what it is set to. It measures the air around it, so if that spot is unusually warm or cold, the whole house suffers.
Fit it:
- on an inside wall, in a room you use a lot, often the living room or a hallway, depending on how the system was designed
- at the height given in the maker’s instructions
- where air can circulate freely around it
Avoid:
- next to or above a radiator, fire or other heat source
- in direct sunlight
- in draughts from doors, windows or stairs
- in kitchens, where cooking skews the reading
- behind curtains or furniture, or near lamps, TVs or other electronics that give off heat
Do not fit a thermostatic radiator valve in the same room as the room thermostat. If the TRV shuts the radiator off before the thermostat is satisfied, the thermostat keeps calling for heat and the boiler runs on while the rest of the house overheats. If there has to be a TRV, set it higher than the thermostat. Our guide to radiator not heating up covers what else can upset the balance between rooms.
What temperature should a room thermostat be set to?
The Energy Saving Trust advises setting it to the lowest comfortable temperature, which for most people is between 18 and 21 degrees. Homes with babies, older people or anyone unwell may need it a little warmer.
Tips that make a real difference:
- Set it and leave it. Turning it up to 28 does not warm the house any faster. The boiler heats at the same rate, it just carries on for longer.
- Use the timer for when, and the thermostat for how warm. Heat the house for when you need it, not all day.
- Try turning it down one degree. Most people do not notice, and it saves energy over a winter.
- Use TRVs in other rooms. Keep bedrooms and unused rooms cooler.
- Lower the boiler flow temperature as well, where your system allows, so your condensing boiler runs efficiently.
Common room thermostat problems
Heating will not come on
Check these first:
- Is the timer calling for heating? Many problems are simply the programme.
- Is the thermostat set above the current room temperature?
- Does it need new batteries? Many digital and wireless thermostats go blank or lose connection when batteries run low.
- On a wireless thermostat, check the receiver near the boiler has power and shows it is connected. The manual explains the lights.
- Is the boiler showing a fault code or low pressure? If so, the thermostat may be working fine. Our boiler not firing up guide covers the next steps.
Heating will not switch off
The thermostat may be sited somewhere cold or draughty, set too high, faulty, or the wiring or receiver may be stuck calling for heat. Try turning it right down. If the boiler keeps heating, get an engineer to check the controls and any motorised valves.
House is warmer or cooler than the setting
This is usually the thermostat’s position rather than a fault. Sun, a nearby radiator or a draught will throw it off. Moving it, or switching to a wireless model that can be placed better, often solves it.
Safety with controls
- Many wired room thermostats run at mains voltage. Always isolate the power at the fused spur before touching wiring, or leave it to a competent heating engineer or electrician.
- Never open the boiler casing to connect controls. Only a Gas Safe registered engineer should work inside a gas boiler.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows and do not use electrical switches.
What it costs with Vantage
In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts such as a new thermostat or receiver are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
A simple like-for-like swap takes less time than moving a thermostat, adding zoning or fitting a smart system that talks to the boiler. If you are replacing your boiler, the right controls are part of the installation, and you can get your price online in a couple of minutes with our boiler quote tool.
Frequently asked questions
What does a room thermostat do?
It senses the air temperature and switches your heating on when the room is below your setting and off when it reaches it. It keeps the house at a steady temperature without you having to turn the heating on and off yourself.
Will any room thermostat work with my boiler?
Most boilers work with a standard on/off room thermostat. More sophisticated controls that adjust the boiler’s flow temperature often need to be compatible with that boiler’s communication system, so some are brand-specific. Check the boiler manual or ask an engineer before you buy.
Do I need an electrician to replace a thermostat?
A battery thermostat that pairs with an existing receiver is usually straightforward. Wired thermostats often run at mains voltage and connect to the boiler’s wiring, so they should be fitted by a competent heating engineer or electrician.
Is a smart thermostat better than a normal room thermostat?
It does the same basic job, but adds remote control, scheduling and sometimes automatic features. Whether it saves money depends on how you use it. A well placed standard thermostat, used properly with a timer and TRVs, is already effective.
Should I leave the thermostat on all the time?
Leave the thermostat set at your comfortable temperature and let the timer control when the heating runs. Turning the thermostat up and down all day tends to waste energy and makes the house less comfortable.
When to call an engineer
If your heating will not respond to the thermostat, the thermostat is in a poor position, or you want to upgrade to smart or compensating controls, our heating engineers can help. See our smart thermostat installation service or call 01462 506374, answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374