Electricity keeps tripping because a safety device in your consumer unit (fuse box) has detected a fault: an overloaded or short-circuited circuit trips a circuit breaker, and current leaking to earth, often from a faulty appliance or water getting into an outside light or socket, trips an RCD. You can usually find the cause yourself by unplugging appliances and switching circuits back on one at a time, but if it trips with nothing plugged in, or you see scorch marks or smell burning, the fault is in the wiring and needs an electrician.

In short

  • Tripping is the consumer unit doing its job. It is warning you about a fault, not causing one.
  • Circuit breakers (MCBs) trip on overload or a short circuit. RCDs trip when current leaks to earth.
  • A faulty appliance is the most common cause. Kettles, washing machines, dishwashers, ovens and immersion heaters are frequent culprits.
  • If it trips in wet weather, look at outside lights, sockets and garden circuits first.
  • If it still trips with every appliance unplugged, the fault is in the fixed wiring or a fixed appliance. Call an electrician.
  • Never hold a switch up, tape it in place or fit a bigger fuse.

What is actually tripping?

Open the cover of your consumer unit (the flap, not the panel screwed on underneath) and look at the switches. The one that has tripped will be down, or sitting in a middle position.

DeviceWhat it looks likeWhat makes it trip
Main switchUsually the largest switch, often red or labelled Main SwitchNormally only switched off by hand
RCD (residual current device)A wider switch with a test button marked T or Test, often protecting a row of breakersCurrent leaking to earth, which is what happens in an electric shock or with damp or damaged insulation
MCB (miniature circuit breaker)Narrow switches, one per circuit, labelled with a rating such as B6, B16 or B32Too much current (overload) or a short circuit
RCBOA narrow switch with its own test buttonDoes both jobs for a single circuit
Rewireable fuseOlder boards with pull-out fuse carriersThe fuse wire has melted from overload or a fault

Knowing which device went tells you a lot. An RCD trip points to a leak to earth, usually from something wet or damaged. A single MCB trip points to that circuit being overloaded or shorted. Electrical Safety First says an RCD that keeps tripping is likely to mean there is a fault, either with an appliance or the wiring itself, that needs investigating. If you cannot find it yourself, our electrical fault finding service traces it methodically.

If the power has gone and nothing has tripped

If every switch is up but you have no power, the problem is probably outside your home. Check whether neighbours or street lights are also off, then call 105, the free national power cut number, to report it to your network operator. Do not touch the sealed main fuse box or the meter, which belong to the network and the supplier.

How to find the cause, step by step

  1. Switch off or unplug everything on the affected circuits. Include fixed appliances you might forget, such as the immersion heater, the oven, an electric shower or outside lights, by switching them off at their own switches.
  2. Switch off all the circuit breakers under the RCD that tripped.
  3. Reset the RCD by pushing it firmly back up. If it will not stay up with every breaker off, stop and call an electrician.
  4. Switch the breakers back on one at a time. When one trips the RCD again, that is the circuit with the fault. Leave it off and restore the others.
  5. On the faulty circuit, plug appliances back in one at a time. If the RCD or breaker trips as soon as one is plugged in or switched on, you have probably found a faulty appliance. Leave it unplugged and get it repaired or replaced.
  6. If it trips with nothing plugged in, the fault is in the fixed wiring, a socket, a light fitting or a fixed appliance. This needs an electrician.

For a single MCB tripping, the same idea applies: unplug the things on that circuit, reset the breaker, then add them back one by one. If it trips when you run several heavy loads together, such as a kettle, a microwave and a heater on one kitchen circuit, it is likely an overload, and spreading the load stops it.

Stay safe

  • Never force a switch or hold it in the on position, and never tape it up. It trips to protect you.
  • Never replace fuse wire or a fuse with a higher rating than stated.
  • Never remove the screwed-on cover of the consumer unit or work on sockets and fittings yourself.
  • If you see scorch marks, smell burning, hear buzzing or crackling, or the consumer unit feels hot, switch off at the main switch if it is safe and call an electrician straight away.
  • If anyone has had an electric shock, switch off the power before touching them and call 999.

Common causes of tripping electrics

CauseWhat you might noticeCan you fix it yourself?What the electrician does
Faulty applianceTrips when a particular appliance is switched on, often a kettle, washing machine or ovenYes, by unplugging it and replacing or repairing itTests the appliance or confirms the circuit is sound
Overloaded circuitOne breaker trips when several high power appliances run togetherYes, by spreading the loadChecks the circuit design and cable sizes, adds a circuit if needed
Water ingressRCD trips in rain or after washing the car, outside lights or sockets affectedPartly, by switching off outside circuitsFinds and seals or replaces the wet fitting
Faulty immersion heater elementTrips when the hot water comes on, sometimes on a timerNoTests the element and replaces it
Damaged cableTrips after DIY, for example a nail or screw into a wallNoFinds the damage and repairs the cable safely
Worn or faulty breaker or RCDTrips with no pattern, or will not resetNoTests the device and replaces it
Several small leaks adding upOlder boards where one RCD protects many circuits, random tripsNoTests each circuit, may recommend an upgraded consumer unit

When it trips at night or at the same time each day

Anything on a timer is a suspect: the immersion heater on an off-peak setting, outside lights on a sensor, a pump or the heating. A fridge or freezer that has developed a fault can trip the power when its defrost heater or compressor switches on.

When it trips in wet weather

Outside sockets, garden lighting, garage and shed supplies and anything in an exposed position are the first places to look. Water in a fitting lets current leak to earth, and the RCD reacts.

Test your RCD

The test button on an RCD checks that its trip mechanism works. Press it and the RCD should switch off; then push it back up. The label on or near your consumer unit says how often to test it, so follow that. If it does not trip when you press the button, the RCD may not protect you, and it needs checking.

When a tripping problem needs an electrician

Call a qualified electrician if:

  • the RCD or a breaker trips with everything unplugged or switched off;
  • it will not reset at all;
  • you have found the faulty circuit but cannot find the cause;
  • the trips keep coming back after you have removed the suspect appliance;
  • there are signs of heat, burning or damage;
  • your home still has an old board with rewireable fuses or no RCD protection.

An electrician tests the insulation of each circuit to find where current is leaking, checks the connections and devices, and repairs or replaces the faulty part. Our guide to choosing an electrician explains what to look for. If your wiring is ageing, an EICR electrical safety check shows its condition, and Electrical Safety First recommends homeowners have their electrics checked about every ten years. If you rent your home out, the electrical safety rules for private landlords require an inspection at least every five years.

Replacing a consumer unit is notifiable work under Part P of the Building Regulations in England, so it must be done by a registered electrician who can certify it. We can quote for this under our electrical installations service.

What it costs with Vantage

In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. Larger work, such as a new consumer unit, is quoted as a fixed price.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Frequently asked questions

Why does my RCD keep tripping with nothing plugged in?

If the RCD trips with every appliance unplugged and fixed appliances switched off, the fault is in the fixed wiring, a socket, a light fitting or a fixed appliance like an immersion heater. This needs an electrician with insulation testing equipment to find it.

Can a faulty appliance trip the whole house?

Yes. On many consumer units one RCD protects several circuits, so a fault in one appliance can switch off a large part of the house. Unplugging appliances and resetting circuits one at a time finds it.

Does a breaker need replacing if it keeps tripping?

Usually not. A breaker that keeps tripping is normally reacting correctly to a real fault. Occasionally the breaker or RCD itself wears out, which an electrician can confirm by testing it.

Why does my electricity trip when it rains?

Rain getting into an outside socket, light, junction box or cable lets current leak to earth, and the RCD trips to protect you. Switch off the outside circuit until an electrician has found and fixed the wet fitting.

Is it dangerous if my electrics keep tripping?

The tripping itself is a safety device working. The fault behind it can be dangerous, especially if there are scorch marks, a burning smell or damaged cables, so do not ignore repeated trips.

Electrical help in Hertfordshire, Bedfordshire and Cambridgeshire

If your electrics keep tripping and you cannot find the cause, our electricians can trace and fix it. See our electrical repairs and fault finding page, or for a fault that cannot wait, our emergency electrician service. Call 01462 506374. The phone is answered 24 hours a day, 7 days a week.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.