How to Repressurise a Worcester Bosch Boiler: Step-by-Step Guide

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

To repressurise a Worcester Bosch boiler, turn the heating off, find the filling device under the boiler (a white filling key, a blue keyless lever or a silver external hose) and let water in slowly until the gauge reads between 1 and 1.5 bar, which is the range Worcester gives in its homeowner guide. Close the valve, then reset the boiler if it is showing a fault; if you have to do this more than once or twice a year, there is a leak or a faulty part that needs an engineer.

In short

  • Worcester’s target is 1 to 1.5 bar with the system cold. It will rise when the heating runs.
  • Worcester boilers use one of three filling methods: a keyed filling link, a keyless filling link with a blue lever, or an external filling loop.
  • Always fill slowly and watch the gauge. Stop as soon as the needle reaches the green zone.
  • If you overfill, let the system cool and bleed a radiator to bring the pressure down.
  • Pressure that keeps dropping points to a leak, a weeping pressure relief valve or an expansion vessel that has lost its charge.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

Check the pressure first

Look at the pressure gauge with the heating off and the boiler cool. On most Greenstar boilers it is a small dial on the front; on some newer models it is a number on the display.

Worcester’s own guidance for the Greenstar range is that the gauge should read around 1 bar with the heating off, and that it will usually rise to 1.5 bar or more while the boiler is running. Its homeowner guide gives 1 to 1.5 bar as the correct range when filling, and the gauge on many models has a green zone marking that band.

Reading (heating off, system cool)What it meansWhat to do
Below 0.5 barVery low. The boiler is likely to stop and show a faultTop up to 1 to 1.5 bar
0.5 to 1 barLow. The boiler may cut outTop up to 1 to 1.5 bar
1 to 1.5 barCorrectNothing to do
Around 1.5 to 2 bar with the heating onNormal while runningNothing to do
Close to 3 barToo high. The pressure relief valve may openLet it cool, then bleed a radiator

A boiler that has lost pressure often shows a fault as well as a low reading. On many Greenstar models that is A1 with cause code 281, which our Worcester A1 guide explains. Our full list of Worcester Bosch fault codes covers the rest. If the pressure is fine and the boiler still will not work, the problem lies elsewhere and our boiler repair engineers can find it.

Which filling method does your Worcester have?

Worcester combi and system boilers are sealed systems, so they need topping up by hand from time to time. There are three ways Worcester boilers are filled, and the steps are different for each. Look underneath the boiler first.

MethodWhat you will seeCommon on
Keyed filling linkA white plastic key, often clipped under the boiler or behind a small flap, that pushes into a socket marked with padlock symbolsMany Greenstar combis
Keyless filling linkA black manifold with a blue lever, usually on the right-hand side underneathSupplied as standard with the Greenstar CDi Classic combi, and fitted to other models as an accessory
External filling loopA braided silver hose between two small valves on the pipes under the boiler, or a hose stored separately with a capped valveSystem boilers and some older installations

On some models the key or lever sits behind a small clip-off cover under the boiler, and Worcester’s homeowner guide shows you how to lower it. That cover is not the boiler casing. Never remove the front casing or undo any screws on the boiler itself.

A regular (heat-only) boiler with a small tank in the loft has no filling device, because the tank tops the system up itself.

How to top up with a keyed filling link

  1. Turn the heating and hot water off and let the boiler cool. Pressure rises as water heats, so filling a hot system gives a false reading.
  2. Find the key. It is usually stored under the boiler. If it is missing, see the FAQ below.
  3. Line up the arrow on the key with the open padlock symbol and push it fully into the socket.
  4. Turn the key about 45 degrees to lock it in, as your user guide shows.
  5. Open the filling tap slowly by turning it anticlockwise. You will hear water running into the system.
  6. Watch the gauge. Stop as soon as the needle reaches between 1 and 1.5 bar.
  7. Close the tap fully, turn the key back to the open padlock and pull it out. Keep it somewhere safe, clipped back under the boiler if there is a holder.
  8. Turn the boiler back on and reset it if it is showing a fault.

How to top up with a keyless filling link

  1. Turn the heating off and let the boiler cool.
  2. Find the blue lever on the black manifold underneath, usually on the right.
  3. Pull the lever down and hold it. Water starts to flow into the system.
  4. Watch the gauge. Release the lever when the needle reaches between 1 and 1.5 bar. It closes on its own when you let go.
  5. Reset the boiler if a fault is showing.

How to top up with an external filling loop

  1. Turn the heating off and let the boiler cool.
  2. Find the two small valves on the pipes under the boiler. If the hose is stored separately, remove the cap from the valve and connect the hose to both ends by hand.
  3. Open one valve fully, then open the second valve slowly. Water starts to flow.
  4. Watch the gauge and close both valves (levers across the pipe) when it reaches between 1 and 1.5 bar.
  5. Disconnect the hose if it is the removable type and refit the cap. Worcester’s guidance is to remove the hose and refit the cap once filling is finished. A removable filling loop is only meant to be connected while you fill.
  6. Reset the boiler if needed.

On a system boiler, the filling loop is sometimes in the airing cupboard next to the hot water cylinder rather than under the boiler. If you cannot tell which valve does what, stop there and ask an engineer. Opening the wrong valve can drain the system rather than fill it.

What not to do

  • Do not remove the boiler casing or touch anything inside it. Only a Gas Safe registered engineer may work inside a gas boiler.
  • Do not fill a hot system. Wait until it has cooled.
  • Do not leave a filling valve open and walk away. The pressure keeps rising.
  • Do not keep resetting a boiler that locks out again straight after topping up. Call an engineer.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows and do not use electrical switches.

If you put too much water in

It is easy to overshoot, especially with an external loop. If the gauge reads above 1.5 bar with the system cold, let everything cool and then bleed a radiator: open the bleed valve with a radiator key, hold a cloth underneath and let water out until the gauge drops back into range. Worcester gives this same advice. Our guide on how to bleed a radiator walks through it.

Do not leave the pressure close to 3 bar, where the pressure relief valve opens and lets water out through a pipe that usually runs outside.

Why does a Worcester boiler lose pressure?

Topping up once or twice a year is normal, often after bleeding radiators. More than that means water is leaving the system, or the part that absorbs expansion has stopped working.

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Air bled from radiatorsPressure drops right after bleedingYes, top up onceNothing needed
Small leak on a radiator valve or jointDrips, stains or green crusting on a valveSometimes, if it is a loose visible fittingTraces and repairs the leak
Hidden leak under a floorPressure drops but no visible waterNoChecks the system and arranges leak detection if needed
Pressure relief valve letting byDrips from the small copper pipe outside, often after the pressure risesNoTests and replaces the valve
Expansion vessel lost its chargePressure swings high when hot, low when coldNoRecharges the vessel or replaces it
Leak inside the boilerWater under the boiler or inside the caseNoFinds and repairs the internal leak

Worcester’s own troubleshooting advice is to check all visible joints and radiator valves for leaks and to check that no water is coming out of the pressure relief valve pipe. Both are safe for you to look at. Our guide to a boiler that keeps losing pressure goes into each cause in more detail.

Frequent topping up also brings in fresh mains water, which dilutes the inhibitor that protects your system from corrosion, and Hertfordshire’s hard water adds minerals each time.

When to call an engineer

Call a Gas Safe registered engineer if the pressure drops again within weeks, water drips from the boiler or the relief pipe outside, the pressure rises very high when the heating is on, the boiler still shows a fault with the pressure correct, or you cannot find or safely operate the filling device.

We repair and service all the major brands, including Worcester Bosch. An annual boiler service includes checking the pressure, the expansion vessel charge and the relief valve, which is where many slow pressure losses start.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. Our repairs carry a 12 month labour guarantee.

Frequently asked questions

What should the pressure be on a Worcester Bosch boiler?

Worcester gives 1 to 1.5 bar with the system cold. When the heating is running, it will usually rise to around 1.5 bar or a little more, which is normal. If it gets close to 3 bar, it is too high.

I have lost my Worcester filling key. What can I do?

Do not try to open the filling link with a screwdriver or pliers, as you can damage it. Replacement keys are available from plumbing merchants, and Worcester sells a keyless filling link as an accessory that an engineer can fit in its place. An engineer can also top the system up for you on a visit.

Why is my Worcester boiler pressure too high?

Usually because too much water went in when it was topped up, or a filling valve has been left slightly open. If it only goes high when the heating is on and drops back when cold, the expansion vessel has probably lost its charge and needs an engineer.

Do I need to reset the boiler after topping up?

If the boiler showed a fault because of low pressure, it may need a reset once the pressure is correct. Follow the reset method in your user guide. If it locks out again, stop resetting and call an engineer.

Boiler help in Hertfordshire, Bedfordshire and Cambridgeshire

If your Worcester keeps losing pressure or will not restart after topping up, our Gas Safe registered engineers (registration 956889) can find the cause. We are rated 4.9 on Google and our phone is answered 24 hours a day, 7 days a week. See our boiler repair page or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.